Prysmian and Draka Cable 3 Cores 95 Cross-section core BFCU 0.6/1kV Power, Fire Resistant and Halogen free Cable 840309

Prysmian and Draka Cable 3 Cores 95 Cross-section core BFCU 0.6/1kV Power, Fire Resistant and Halogen free Cable 840309

Select gauge from drop-down menu for prices:

Prysmian and Draka Cable 3 Cores 95 Cross-section core BFCU 0.6/1kV Power, Fire Resistant and Halogen free Cable 840309
Prysmian and Draka Cable 3 Cores 95 Cross-section core BFCU 0.6/1kV Power, Fire Resistant and Halogen free Cable 840309

Conductor: Tinned stranded circular copper, BS 6360, class 2

Insulation: Mica glass tape / EP-rubber, GP4 to BS 7655: section 1.2

Lay up / Shielding: Cores laid up in concentric layers

Inner covering: Flame retardant and halogen-free thermoplastic EP-rubber based compound

Tape over inner covering: PET tape + rubberized Polyamide tape

Armour/screen: Galvanized steel wire braid

Tape over armour/screen: PET + tape rubberised Polyamide tape

Outer sheath: Flame retardant, halogen-free, enhanced oil-resisting thermoset compound (LSF), SW4 to BS 7655 section 2.6

Marking text: "metre mark" "year" "DRAKA" "BFCU" "UKOOA code" "600/1000V" "number of cores" "conductor size" "BS7917" "IEC60331-21" "IEC60332-3-22" (marking may differ on cable actually supplied)

Outer sheath colour: Black

Operating temperature: 90°C

Operating Voltage: 0.6/1kV

Standards applied:
• BS7917/BS6883/UKOOA - Design
• BS6360 class 2 - Conductor
• BS7655 section 1.2 - Insulation
• BS7655 section 2.6 - Sheath
• IEC 60332-1 & 3-22 - Flame Retardant
• IEC60331-21 - Fire Resistant
• IEC60754-1,2 - Halogen Free
• IEC 61034-1,2 - Low Smoke

Core identification: All cores are offwhite with black numbers No 1,2,3....

Description:
• BFCU 0.6/1kV 2X 1.5mm2
• BFCU 0.6/1kV 2X 2.5mm2
• BFCU 0.6/1kV 2X 4mm2
• BFCU 0.6/1kV 2X 6mm2
• BFCU 0.6/1kV 2X 10mm2
• BFCU 0.6/1kV 2X 16mm2
• BFCU 0.6/1kV 2X 35mm2
• BFCU 0.6/1kV 3X 1.5mm2
• BFCU 0.6/1kV 3X 2.5mm2
• BFCU 0.6/1kV 3X 4mm2
• BFCU 0.6/1kV 3X 6mm2
• BFCU 0.6/1kV 3X 10mm2
• BFCU 0.6/1kV 3X 16mm2
• BFCU 0.6/1kV 3X 25mm2
• BFCU 0.6/1kV 3X 35mm2
• BFCU 0.6/1kV 3X 50mm2
• BFCU 0.6/1kV 3X 70mm2
• BFCU 0.6/1kV 3X 95mm2
• BFCU 0.6/1kV 4X 1.5mm2
• BFCU 0.6/1kV 4X 2.5mm2
• BFCU 0.6/1kV 4X 4mm2
• BFCU 0.6/1kV 4X 6mm2
• BFCU 0.6/1kV 4X 35mm2
• BFCU 0.6/1kV 4X 70mm2
• BFCU 0.6/1kV 7X 1.5mm2
• BFCU 0.6/1kV 7X 2.5mm2
• BFCU 0.6/1kV 12X 1.5mm2
• BFCU 0.6/1kV 12X 2.5mm2
• BFCU 0.6/1kV 19X 2.5mm2
• BFCU 0.6/1kV 27X 2.5mm2

Sheath Colour: BLACK

Design standard:
• BS 7917 : 1999
• BS 6883 : 1991

Application:
• Armoured cable for fixed installation for power, control or lighting in both EX and safe areas, emergency and critical systems where there is a requirement for fire reistant cables.
• Enhanced MUD resistant version also available for use in areas exposed to mud and drilling / cleaning fluids, meeting the mud resistance requirement in NEK 606.

technical specification:
number of cores 3
cross-section core, mm2 95
conductor diameter, mm 12.6
insulation thickness, mm 1.6
thickness inner sheath, mm 2.2
approx. diameter inner sheath, mm 39.5
diameter braid wire, mm 0.45
thickness outer sheath, mm 2.4
approx. overall diameter, mm 46.5
weight of cable approx. (kg/km) 4950
copper content approx. (kg/km) 2513
max. conductor resistance at 20°c, ohm/km 0.195
max. conductor resistance at 90°c, ohm/km 0.249
reactance at 50hz, ohm/km 0.075
reactance at 60hz, ohm/km 0.09
current rating iec 60092-352 table b.4, ampere 205
short circuit rating 1 second, ampere 13300
ukooa code yd395
prysmian and draka cable part number 840309