Prysmian Cable 1 AWG Ecosafe Copper Low Voltage Commercial and Industrial 600 Volt Cable 033024BK
Select gauge from drop-down menu for prices:
- Prysmian Cable Ecosafe Copper Low Voltage Commercial and Industrial 600 Volt Cable
- Prysmian Cable 14 AWG Ecosafe Copper Low Voltage Commercial and Industrial 600 Volt Cable 033270BK
- Prysmian Cable 12 AWG Ecosafe Copper Low Voltage Commercial and Industrial 600 Volt Cable 033016BK
- Prysmian Cable 10 AWG Ecosafe Copper Low Voltage Commercial and Industrial 600 Volt Cable 033017BK
- Prysmian Cable 8 AWG Ecosafe Copper Low Voltage Commercial and Industrial 600 Volt Cable 033019BK
- Prysmian Cable 6 AWG Ecosafe Copper Low Voltage Commercial and Industrial 600 Volt Cable 033020BK
- Prysmian Cable 4 AWG Ecosafe Copper Low Voltage Commercial and Industrial 600 Volt Cable 033021BK
- Prysmian Cable 2 AWG Ecosafe Copper Low Voltage Commercial and Industrial 600 Volt Cable 033023BK
- Prysmian Cable 1/0 AWG Ecosafe Copper Low Voltage Commercial and Industrial 600 Volt Cable 033025BK
- Prysmian Cable 2/0 AWG Ecosafe Copper Low Voltage Commercial and Industrial 600 Volt Cable 033038BK
- Prysmian Cable 3/0 AWG Ecosafe Copper Low Voltage Commercial and Industrial 600 Volt Cable 033026BK
- Prysmian Cable 4/0 AWG Ecosafe Copper Low Voltage Commercial and Industrial 600 Volt Cable 033028BK
- Prysmian Cable 250 MCM Ecosafe Copper Low Voltage Commercial and Industrial 600 Volt Cable 033067BK
- Prysmian Cable 350 MCM Ecosafe Copper Low Voltage Commercial and Industrial 600 Volt Cable 033029BK
- Prysmian Cable 500 MCM Ecosafe Copper Low Voltage Commercial and Industrial 600 Volt Cable 033030BK
- Prysmian Cable 750 MCM Ecosafe Copper Low Voltage Commercial and Industrial 600 Volt Cable 033481BK
Conductor: Annealed, Class B, concentric compressed,round, bare copper strand as standard. Other optional strandings per ASTM are available for increased flexibility.
Insulation: A dual-layer product where the inner and outer layers are co-extruded, resulting in a tightly bonded system. The inner layer utilizes an EPR-based compound and is optimized for superior electrical properties. The outer layer is EVA-based and is specifically formulated to provide a rugged outer covering, with the additional benefits of limited-smoke and halogen-free materials. Both layers are cross-linked polyolefins.
Description: Single conductor 600 Volt RHW-2 or USE-2 non-halogenated cable with stranded copper conductors,extruded insulation system consisting of a thermosetting polyolefin inner insulation, and a thermosetting polyolefin outer insulation.
Specification:
• ICEA- ICEA S-95-658
• ICEA- ICEA S-105-692
• UL- UL 1685 ST1
• UL- UL 854
• UL- UL Subject 758
• UL- UL Subject 509
• IEEE- IEEE 1202 Flame Test
• CSA- CSA C22.2 No. 0.3
• CSA- CSA C22.2 No.210.2
• Bellcore - Bellcore GR-347-CORE
• NFPA- NFPA 130 2014 Code Compliant
Ratings:
• Type II EPR
• Type II EPR
• Type RHW-2, Class XL FT4 / ST1 (Low Smoke) VW-1
• For CT USE (1/0 AWG and Larger) Oil Resistance II
• Sunlight Resistant (black, red, grey and dark colors
• Type USE-2
• AWM 105°C (Style 3167 and 3578)
• Miscellaneous Wire for Telephone Central Office
• FT-1 (#6 AWG and Larger)
• FT-4
• AWM Class I, Group A/B, Rated 105°C
Options:
• Class C, Class D, Class G and Class I conductor strandings per ASTM
• Tin-coated conductor
• Type RW90 (-40°C, SR) per CSA C22.2 No. 38
• Colorable
technical specification | |
conductor | 1 awg |
insulation thickness (mils) | 80 |
condutor diameter (in.) | 0.322 |
condutor diameter (mm) | 8.18 |
overall diameter (in.) | 0.51 |
overall diameter (mm) | 12.83 |
cable weight (lbs/kft) | 340 |
ampacity (amps) 90°c in free air | 220 |
prysmian cable part number | 033024BK |