Belden 2121A Cable 18 AWG 8 Pairs Foundation Fieldbus or ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7x26 TPE Jacket 600V Cable

Belden 2121A Cable 18 AWG 8 Pairs Foundation Fieldbus or ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7x26 TPE Jacket 600V Cable

Select gauge from drop-down menu for prices:

Belden 2121A Cable 18 AWG 8 Pairs Foundation Fieldbus or ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7x26 TPE Jacket 600V Cable
Belden 2121A Cable 18 AWG 8 Pairs Foundation Fieldbus or ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7x26 TPE Jacket 600V Cable

Description:
• 8 pair, 18 AWG, Stranded (7x26) Tinned Copper, Individually Foil Shielded Pairs, Overall Beldfoil Shield, Tinned Copper Drain Wires, XLP Insulation, Sunlight- and oil-resistant TPE jacket

Insulation:
• Material: XLP - Cross-Linked Polyolefin

Inner Shield:
• Type: Tape
• Inner Shield Material: Aluminum Foil-Polyester Tape

Inner Shield Drain Wire AWG:
• AWG: 20
• Stranding: 7x28
• Conductor Material: TC - Tinned Copper

Outer Shield Drain Wire AWG:
• AWG: 18
• Stranding: 7x26
• Conductor Material: TC - Tinned Copper

Outer Jacket:
• Material: TPE - Thermoplastic Elastomer
• Outer Jacket Ripcord: Yes

Mechanical Characteristics (Overall):
• Operating Temperature Range: -25°C Cold Impact, -40°C To +90°C, -55°C Cold Bend
• Bulk Cable Weight: 313 lbs/1000 ft.
• Max. Recommended Pulling Tension: 481 lbs.
• Min. Bend Radius/Minor Axis: 8 in.

Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• NEC/(UL) Specification: TC-ER
• CSA Specification: AWM I A/B II A/B, C22.2 #230 Type TC; C22.2#239 Type CIC
• EU Directive 2011/65/EU (ROHS II): Yes
• EU CE Mark: Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes
• Other Specification: IEC 61158-2 (ISA/SP-50) Type A

Electrical Characteristics (Overall):
• Unaveraged Impedance (Ohm): 100.000
• Nom. Inductance (μH/ft): 0.220
• Nom. Capacitance Condutor to Conductor (pF/ft): 22.000
• Maximum Capacitance Unbalance (pF/ft): 1.200
• Nominal Velocity of Propagation (VP %): 64.000
• Nom. Conductor DC Resistance @ 20°C (Ohm/1000 ft): 5.86
• Max. Operating Voltage - UL: 600 V RMS
• Max. Operating Voltage - Other: 600V RMS (CSA CIC type TC)
• Max. Recommended Current: 7.6 Amps/Conductor

Flame Test:
• UL Flame Test: UL1581 Vertical Tray
• CSA Flame Test: FT4
• IEC Flame Test: 60332-3-24 (Category C)

Suitability:
• Suitability - Indoor: Yes
• Suitability - Outdoor: Yes
• Sunlight Resistance: Yes
• Oil Resistance: Yes

Plenum/Non-Plenum:
• Plenum(Y/N): No

technical specification:
awg 18
# pairs 8
stranding 7x26
no. of conductors 16
conductor material tinned copper
diameter (in.) -
outer shield - type tape
outer shield - material aluminum Foil-polyester tape
overall cable - nominal diameter (in.) 0.800
belden cable part number 2121A