Belden 1336A Cable 14 AWG 1 Pair Foundation Fieldbus or ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7x22 PVC Jacket Cable

Belden 1336A Cable 14 AWG 1 Pair Foundation Fieldbus or ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7x22 PVC Jacket Cable

Select gauge from drop-down menu for prices:

Belden 1336A Cable 14 AWG 1 Pair Foundation Fieldbus or ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7x22 PVC Jacket Cable

Precio habitual $7.61 $5.40 Oferta /per Foot

Belden 1336A Cable 14 AWG 1 Pair Foundation Fieldbus or ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7x22 PVC Jacket Cable

Description:
• 1 pair, 14 AWG stranded (7x22) tinned copper conductors, polyolefin insulation, Beldfoil® shield (100% coverage) plus a tinned copper braid shield (65% coverage), tinned copper drain wire, oil-resistant PVC jacket.

Insulation:
• Material: PO - Polyolefin

Outer Shield Drain Wire AWG:
• AWG: 18
• Stranding: 7x26
• Conductor Material: TC - Tinned Copper

Outer Jacket:
• Material: PVC - Polyvinyl Chloride
• Outer Jacket Ripcord: Yes

Mechanical Characteristics (Overall):
• Operating Temperature Range: -30°C To +90°C
• UL Temperature Rating: 90°C
• Max. Recommended Pulling Tension: 131 lbs.
• Min. Bend Radius/Minor Axis: 4.300 in.

Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• EU Directive 2011/65/EU (ROHS II): Yes
• EU CE Mark: Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 09/05/2006
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes

Electrical Characteristics (Overall):
• Unaveraged Impedance (Ohm): 100
• Nom. Capacitance Conductor to Shield (pF/ft): 45.0
• Nom. Mutual Capacitance (pF/ft): 24.0
• Maximum Capacitance Unbalance (pF/ft): 1.2
• Nominal Velocity of Propagation: VP (%): 66
• Nom. Conductor DC Resistance @ 20°C (Ohm/1000 ft): 2.5
• Maximum Outer Shield DC Resistance @ 20°C (Ohm/1000 ft): 4.9
• Max. Operating Voltage - UL: 300 V RMS
• Max. Recommended Current: 5.2 Amps/Conductor

Flame Test:
• UL Flame Test: UL1685 FT4 Loading

Suitability:
• Suitability - Indoor: Yes
• Suitability - Outdoor: Yes
• Sunlight Resistance: Yes

Plenum/Non-Plenum:
• Plenum(Y/N): No

technical specification:
awg 14
# pairs 1
stranding 7x22
no. of conductors 2
conductor material tinned copper
diameter (in.) -
outer shield - type tape
outer shield - material aluminum foil-polyester tape
overall cable - nominal diameter (in.) 0.430
belden cable part number 1336A

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.

Ask a Question