General Cable FREP® FR-EPR CPE Type TC 18 AWG 50 Pairs Overall Shielded Instrumentation Shielded 600V UL
Select gauge from drop-down menu for prices:
- General Cable FREP® FR-EPR CPE Type TC Overall Shielded Pairs Triads Instrumentation Shielded 600V UL
- General Cable FREP® FR-EPR CPE Type TC 18 AWG 1 Pair Overall Shielded Instrumentation Shielded 600V UL
- General Cable FREP® FR-EPR CPE Type TC 18 AWG 1 Triad Overall Shielded Instrumentation Shielded 600V UL
- General Cable FREP® FR-EPR CPE Type TC 18 AWG 2 Pairs Overall Shielded Triads Instrumentation Shielded 600V UL
- General Cable FREP® FR-EPR CPE Type TC 18 AWG 4 Pairs Overall Shielded Triads Instrumentation Shielded 600V UL
- General Cable FREP® FR-EPR CPE Type TC 18 AWG 8 Pairs Overall Shielded Triads Instrumentation Shielded 600V UL
- General Cable FREP® FR-EPR CPE Type TC 18 AWG 12 Pairs Overall Shielded Instrumentation Shielded 600V UL
- General Cable FREP® FR-EPR CPE Type TC 18 AWG 16 Pairs Overall Shielded Instrumentation Shielded 600V UL
- General Cable FREP® FR-EPR CPE Type TC 18 AWG 20 Pairs Overall Shielded Instrumentation Shielded 600V UL
- General Cable FREP® FR-EPR CPE Type TC 18 AWG 24 Pairs Overall Shielded Instrumentation Shielded 600V UL
- General Cable FREP® FR-EPR CPE Type TC 18 AWG 36 Pairs Overall Shielded Instrumentation Shielded 600V UL
- General Cable FREP® FR-EPR CPE Type TC 16 AWG 1 Pair Overall Shielded Instrumentation Shielded 600V UL
- General Cable FREP® FR-EPR CPE Type TC 16 AWG 1 Triad Overall Shielded Instrumentation Shielded 600V UL
- General Cable FREP® FR-EPR CPE Type TC 16 AWG 2 Pairs Overall Shielded Instrumentation Shielded 600V UL
- General Cable FREP® FR-EPR CPE Type TC 16 AWG 4 Pairs Overall Shielded Instrumentation Shielded 600V UL
- General Cable FREP® FR-EPR CPE Type TC 16 AWG 8 Pairs Overall Shielded Instrumentation Shielded 600V UL
- General Cable FREP® FR-EPR CPE Type TC 16 AWG 12 Pairs Overall Shielded Instrumentation Shielded 600V UL
- General Cable FREP® FR-EPR CPE Type TC 16 AWG 16 Pairs Overall Shielded Instrumentation Shielded 600V UL
- General Cable FREP® FR-EPR CPE Type TC 16 AWG 20 Pairs Overall Shielded Instrumentation Shielded 600V UL
- General Cable FREP® FR-EPR CPE Type TC 16 AWG 24 Pairs Overall Shielded Instrumentation Shielded 600V UL
- General Cable FREP® FR-EPR CPE Type TC 16 AWG 36 Pairs Overall Shielded Instrumentation Shielded 600V UL
- General Cable FREP® FR-EPR CPE Type TC 16 AWG 50 Pairs Overall Shielded Instrumentation Shielded 600V UL
Conductor:
• 18 AWG and 16 AWG tinned, annealed copper per ASTM B33
• Class B stranding per ASTM B8
Insulation:
• Flame-Retardant Ethylene Propylene Rubber (FR-EPR) Type II
• Color-coded per ICEA Method 1: Pairs - black and white; Triads - black, white and red. One conductor in each pair or triad is printed alphanumerically for easy identification
Shield:
Overall shielded pairs/triads: Overall shield is Flexfoil® aluminum/polymer in contact with stranded tinned copper drain wire
Jacket: Lead-free, flame-retardant, thermoplastic Chlorinated Polyethylene (CPE)
Applications:
• In free air, raceways or direct burial
• In wet or dry locations
• Permitted for use in Class I, Division 2 industrial hazardous locations per NEC
Features:
• Rated at 90?C wet or dry
• Ripcord applied to all cables with jacket thickness of 60 mils or less
• Excellent physical, thermal and electrical properties
• Excellent moisture resistance
• Excellent resistance to compression cuts and heat deformation
• Excellent flame resistance—burns to an ash; does not exhibit thermoplastic drip
• Low coefficient of friction for easy pulling
• Sunlight- and weather-resistant
• Excellent low temperature cold bend characteristics
• Meets cold bend test at -40?C
Compliances:
Industry Compliances:
• UL 1277 Type TC, UL File # E57179
• UL 1581
• ICEA S-73-532/NEMA WC57
• RoHS Compliant
Flame Test Compliances:
• UL 1581/UL 2556 VW-1
• UL 1685 Vertical Flame Test
• IEEE 383
• IEEE 1202
• CSA FT4
• ICEA T-29-520
Other Compliances:
• EPA 40 CFR, Part 261 for leachable lead content per TCLP
• OSHA Acceptable
Packaging: Material cut to length and shipped on non-returnable wood reels
technical specification: | |
cond. size (awg) | 18 |
no. of pairs/triads | 50 |
cond. strand | 7W |
minimum avg. insulation thickness(inches) | 0.025 |
minimum avg. insulation thickness(mm) | 0.64 |
minimum avg. jacket thickness(inches) | 0.080 |
minimum avg. jacket thickness(mm) | 2.03 |
nominal cable o.d.(inches) | 1.555 |
nominal cable o.d(mm). | 39.50 |
copper weight(lbs/1000 ft) | 523 |
copper weight(kg/km) | 778 |
net weight(lbs/1000 ft) | 1144 |
net weight(kg/km) | 1703 |
catalog number | 337080* |