4/0 Xlp Use-2 Rhh Rhw USE4/0BK
Select gauge from drop-down menu for prices:
- Copper XLP USE-2 RHH RHW Wire
- 14 XLP USE-2 RHH RHW-2 Copper Building Wire
- 12 Gauge XLP USE-2 RHH RHW USE12BK
- 10 Gauge XLP USE-2 RHH RHW USE10BK
- 8 Gauge XLP USE-2 RHH RHW USE8BK
- 6 Gauge XLP USE-2 RHH RHW USE6BK
- 4 GAUGE Xlp Use-2 Rhh Rhw USE4BK
- 2 Gauge XLP USE-2 RHH RHW USE2BK
- 1 Gauge XLP USE-2 RHH RHW USE1BK
- 1/0 Xlp Use-2 Rhh Rhw USE1/0BK
- 2/0 Xlp Use-2 Rhh Rhw USE2/0BK
- 3/0 Xlp Use-2 Rhh Rhw USE3/0BK
- 250MCM Xlp Use-2 Rhh Rhw USE250BK
- 300MCM Xlp Use-2 Rhh Rhw USE300BK
- 350MCM Xlp Use-2 Rhh Rhw USE350BK
- 400 MCM Xlp Use-2 Rhh Rhw USE400BK
- 500MCM XLP Xlp Use-2 Rhh Rhw USE500BK
- 600MCM Xlp Use-2 Rhh Rhw USE600BK
- 700 MCM XLP USE-2 RHH RHW USE700BK
- 750MCM Xlp Use-2 Rhh Rhw USE750BK
- 800MCM XLP USE-2 RHH RHW USE800BK
- 900MCM XLP USE-2 RHH RHW USE900BK
- 1000MCM XLP USE-2 RHH RHW USE1000BK
XLP USE RHH RHW 4/0 USE4/0BK XLP USE-2 RHH RHW-2 Copper Wire Product Description: This product employs a single copper conductor that is jacketed in a polyethylene insulation. The polyethylene jacket is a cross-linked insulation that enhances the lifespan of the cable by providing a flexible yet durable armor that protects the conductive components from high heat, moisture, abrasion, and chemicals that may corrode the copper. Copper cables offer many benefits over their aluminum competitors; they have extremely powerful conductive properties and retain their stability for a longer time than aluminum. The construction of XLP/USE-2, RHH, and RHW-2 copper wires offer an optimal combination of electrical and mechanical strength. Applications: This cable is most commonly used within an electrical raceway such as conduit. Conduit is a tube or trough that channels the cable and further protects it from obstacles and abrasion. Conduit can be made of metal or plastic, the best option depending on the task at hand. RHH cable is most suitable for dry locations such as desert regions and should not be used in temperatures over 90°C. RHW-2 and USE-2 are suitable for both wet and dry locations and can tolerate temperatures up to 90°C. Type USE-2 conductors can be used for direct burial for service entrance cable. Specifications: Constructions: - These cables are made with annealed soft copper. Copper is an extremely powerful conductor and has proven its stability over time. - Conductors are insulated with a black cross-linked sunlight resistant insulation. The insulation protects the conductors against excessive heat, dryness, moisture, and abrasion.
Technical Specifications:
Phase Conductor Insulation Thickness:
80 mls
Size AWG:
4/0
Stranding:
19
Diameter Complete Cable (O.D.) (Mils):
673
Weight Per 1000ft Total (Lbs.):
729
Allowable Ampacity 60C (Amps):
195
Allowable Ampacity 75C (Amps):
230
Allowable Ampacity 90C (Amps):
260
Advanced Digital item Part #
3040
Aetna item Part #
120-5600
Draka item Part #
6201091bk
General Cable Part #
16602.2154
Omni Cable Part #
M64/0ST-01
Service Wire Part Number
USE4/0BK