Amercable AmerSol Dual-Certified 14 AWG Photovoltaic Cable Single-Conductor 600V/1000V Rated 90C 37-713-505

Amercable AmerSol Dual-Certified 14 AWG Photovoltaic Cable Single-Conductor 600V/1000V Rated 90C 37-713-505

Amercable AmerSol Dual-Certified 14 AWG Photovoltaic Cable Single-Conductor 600V/1000V Rated 90C 37-713-505

Conductor: Soft annealed tin-coated flexible stranded copper per ASTM B-33 and EN 60228

Insulation: Halogen-free, thermoset polyolefin specifically designed for maximum flexibility

Jacket Black: low smoke non-halogenated, flame retardant, oil, abrasion, chemical and sunlight resistant cross-linked compound meeting UL 44, UL 854 and TÜV 2Pfg1169/08.2007

 Applications:
 Nexans AmerCable’s AmerSol is the first U.S. manufactured solar cable to achieve TÜV and UL certification. This versatile single-conductor cable is designed to meet the varying needs of the Solar Industry. Applications include connection to module junction boxes; required cable routing in balance of system (BOS) integration. Rated 600V UL and 1000V TÜV

Features:
• A two layer construction with a low smoke halogen-free, flame retardant and sunlight resistant cross-linked compound outer layer and halogen-free thermoset polyolefin inner layer.
• Suitable for continuous operating temperature of 90°C wet or dry 
• UL listed as Sunlight Resistant 
• Vertical Flame Performance: EN 60332-1 
• Excellent UV and ozone resistant 
• Suitable for wet, damp and humid locations 
• Specially designed for excellent flexibility 
• Compatible with all major connectors 
• Cold bend and impact: -40°C

Ratings & Approvals:
• TÜV certification 2 Pfg 1169/08.2007
• TÜV listed as PV1-F; 1000V (60038697)
• UL listed as Type USE-2 or RHW-2; 600V (E76090)
• ETL listed as Type PV; 600V (3092993) 
• UL Standard 854: Standard for Safety for Service Entrance Cables, Type USE-2 or RHW-2; 600V
• UL Subject 4703: Outline of Investigation for Photovoltaic Wire, Type PV; 600V
• IEC 60228: Conductors of Insulated Conductors, Class 5
• ASTM B-33: Standard Specification for Tinned Soft or Annealed Copper Wire for Electrical Purposes
• 90°C Temperature Rating; Temperature index in excess of 120°C
• RoHS compliant

technical specification:
size(awg) 14
number of wires 45
nominal inner layer thickness(inches) 0.045
nominal outer layer thickness(inches) 0.030
nominal outer diameter(inches) 0.245
approx. weight(lb/mft) 41
ampacity 90° c 35
amercable part number 37-713-505