Belden 1048A 18 AWG 2 Pairs 600V Multi Conductor Tray Cable
Select gauge from drop-down menu for prices:
- Belden 18 AWG Pairs Individually and Overall Beldfoil Shielding UL Instrumentation 600V Tray Cable
- Belden 1049A 18 AWG 4 Pairs 600V Multi Conductor Tray Cable
- Belden 1050A 18 AWG 8 Pairs 600V Multi Conductor Tray Cable
- Belden 1051A 18 AWG 12 Pairs 600V Multi Conductor Tray Cable
- Belden 1052A 18 AWG 16 Pairs 600V Multi Conductor Tray Cable
- Belden 1053A 18 AWG 24 Pairs 600V Multi Conductor Tray Cable
- Belden 1054A 18 AWG 36 Pairs 600V Multi Conductor Tray Cable
- Belden 1038A 18 AWG 50 Pairs 600V Multi Conductor Tray Cable
Product Details
Description:
• 18 AWG pairs stranded (7x26) bare copper conductors, twisted pairs, PVC/Nylon insulation, individually shielded plus an overall Beldfoil shield (100% coverage), PVC jacket.
Insulation:
• Material: PVC/Nylon - Polyvinyl Chloride/Nylon
Inner Shield:
• Trade Name: Beldfoil®
• Type: Tape
• Material: Aluminum Foil-Polyester Tape
Inner Shield Drain Wire AWG:
• AWG: 20
• Stranding: 7x28
• Material: TC - Tinned Copper
Outer Shield Drain Wire AWG:
• AWG: 18
• Stranding: 7x26
• Material: TC - Tinned Copper
Outer Jacket:
• Material: PVC - Polyvinyl Chloride
• Nom. Wall Thickness (mm): 1.2192
• Outer Jacket Ripcord: Yes
Overall Cabling Lay Length and Direction:
• Length (in.): 4.0
Mechanical Charactertistics (Overall):
• Wet Temperature Range: -30°C To +75°C
• Dry Temperature Range: -30°C To +90°C
• Bulk Cable Weight: 77 lbs/1000 ft.
• Max. Recommended Pulling Tension: 140 lbs.
• Min. Bend Radius/Minor Axis: 3.800 in.
Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• NEC/(UL) Specification: NPLF, TC-ER
• EU Directive 2011/65/EU (ROHS II): Yes
• EU CE Mark: Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 04/01/2005
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes
• Other Specification: ICEA S-73-532 (WC57), S-61-402
Electrical Characteristics (Overall):
• Nom. Conductor DC Resistance @ 20°C (Ohm/1000 ft): 5.86
• Nominal Outer Shield DC Resistance @ 20°C (Ohm/1000 ft): 4.91
• Ind. Pair Nominal Shield DC Resistance @ 20 Deg. C: 7.460 Ohm/1000 ft
• Max. Operating Voltage - UL: 600 V RMS (NEC Type TC)
• Max. Operating Voltage - UL: 150 V RMS (NPLF)
Flame Test:
• UL Flame Test: UL1685 UL Loading
• C(UL) Flame Test: FT4
• IEEE Flame Test: 1202
Suitability:
• Suitability - Burial: Yes
• Sunlight Resistance: Yes
Plenum/Non-Plenum:
• Plenum (Y/N): No
technical specification: | |
awg | 18 |
# paris | 2 |
stranding | 7x26 |
no. of conductors | 4 |
conductor material | bare copper |
outer shield - type | tape |
outer shield - material | aluminum foil-polyester tape |
overall cable- nominal dia. (mm) | 9.601 |
belden cable part number | 1048A |