Mechanical Charactertistics (Overall):
• Bulk Cable Weight: 47.622 Kg/Km
Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• ANSI Specification: MC 96.1-1982 Type KX
Surface Printing (Overall):
Electrical Characteristics (Overall):
• Nom. Conductor DC Resistance @ 20°C (Ohm/km): 541.365 (CHROMEL)
• Nom. Conductor DC Resistance @ 20°C (Ohm/km): 216.546 (ALUMEL)
Flame Test:
• ICEA Flame Test: T-29-520
technical specification: | |
awg | 16 |
# pairs | 1 |
stranding | solid |
no. of conductors | 2 |
conductor material | chromel and alumel |
ansi type | KX |
outer shield - type | tape |
outer shield - material | aluminum foil-polyester tape-aluminum foil |
overall cable- nominal dia. (mm) | 4.343 |
belden cable part number | 1116A |