Belden 1311A Cable 12 AWG 2 Conductors Oxygen-Free High Conductivity Speaker Cable
Select gauge from drop-down menu for prices:
- Belden Cable 16 to 10 AWG Multi-Conductor Oxygen-Free High Conductivity Speaker Cable
- Belden 1307A Cable 16 AWG 2 Conductors Oxygen-Free High Conductivity Speaker Cable
- Belden 1309A Cable 14 AWG 2 Conductors Oxygen-Free High Conductivity Speaker Cable
- Belden 1313A Cable 10 AWG 2 Conductors Oxygen-Free High Conductivity Speaker Cable
- Belden 1308A Cable 16 AWG 4 Conductors Oxygen-Free High Conductivity Speaker Cable
- Belden 1310A Cable 14 AWG 4 Conductors Oxygen-Free High Conductivity Speaker Cable
- Belden 1312A Cable 12 AWG 4 Conductors Oxygen-Free High Conductivity Speaker Cable
12 AWG stranded (7x24x34) oxygen-free high-conductivity bare copper conductors, PO insulation, PVC jacket. Sequential footage marking every two feet.
Benefits & Features
• All cables feature Electrolytic Tough Pitch (ETP) virgin copper construction. The speaker cable line includes direct burial speaker cable with ultra-high purity (99.995%), sometimes described as "oxygen-free" copper (OFC)
• Belden cables use soft drawn and annealed conductors which allow the cables to be flexed without breaking
• Belden jackets pull easier and are easier to strip, saving installation time and money
Applications:
• Speaker Cable
• Direct Burial
• Indoor/Outdoor Home Theater
• In-Wall Speaker
• Outdoor Speaker
Mechanical Characteristics (Overall):
• Operating Temperature Range: -20°C To +75°C
• UL Temperature Rating: 75°C
• Bulk Cable Weight: 67 lbs/1000 ft.
• Max. Recommended Pulling Tension: 152 lbs.
• Min. Bend Radius/Minor Axis: 3.500 in.
Applicable Specifications and Agency Compliance (Overall):
Applicable Standards & Environmental Programs:
• NEC/(UL) Specification: CL3, CM
• CEC/C(UL) Specification: CM
• EU Directive 2011/65/EU (ROHS II): Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 07/01/2005
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire & Cable): Yes
• MII Order #39 (China RoHS): Yes
Flame Test:
• UL Flame Test: UL1581 Vertical Flame and FT-1 Flame Test
• CSA Flame Test: FT1
Suitability:
• Suitability - Indoor: Yes
• Suitability - Outdoor: Yes
Plenum/Non-Plenum:
• Plenum (Y/N): No
• Plenum Number: 6000UE
technical specification | |
awg | 12 |
#conductors | 2 |
stranding | 7x24x34 |
conductor material dia. (in.) | .102 |
insulation materialdia. (in.) | .140 |
outer shield material | Unshielded |
outer jacket material | PVC |
overall nominal diameter(in.) | 0.352 |
belden cable part number | 1311A |