Belden 1859A Cable 15 AWG Video Triax RG-11/U Type High Flex Plenum Coax Cable
Select gauge from drop-down menu for prices:
- Belden Cable Video Triax Cable
- Belden 8232 Cable 20 AWG Video Triax RG-59/U Type General Coax PE Jacket Cable
- Belden 1856A Cable 20 AWG Video Triax RG-59/U Type General Coax Cable
- Belden 8232A Cable 20 AWG Video Triax RG-59/U Type Riser Coax Cable
- Belden 88232 Cable 20 AWG Video Triax RG-59/U Type Plenum Coax Cable
- Belden 1857A Cable 22 AWG Video Triax RG-59/U Type High Flex General Coax Cable
- Belden 8233A Cable 14 AWG Video Triax RG-11/U Type Riser Coax Cable
- Belden 8233P Cable 14 AWG Video Triax RG-11/U Type Plenum Coax Cable
- Belden 8233WB Cable 14 AWG Video Triax RG-11/U Type Waterblock Coax Cable
- Belden 7803A Cable 14 AWG Video Triax RG-11/U Type Waterblock Coax PE Jacket Cable
- Belden 1858A Cable 15 AWG Video Triax RG-11/U Type High Flex General Coax Cable
Description:
• RG-11/U Type, Plenum-CMP, 15 AWG stranded (19x27) triax, .064" bare copper conductor, plenum, foam FEP insulation, bare copper braid shields (95% and 90% coverage), fluorocopolymer jacket.
Insulation:
• Material: FFEP - Foam Fluorinated Ethylene Propylene
• Dia. (in.): 0.285
Inner Shield:
• Type: Braid
• Material: Bare Copper
Inner Jacket:
• Material: PVDF - Fluorocopolymer
• Nom. Dia. (in.): 0.350
Outer Jacket:
• Material: PVDF - Fluorocopolymer
Mechnical Characteristics (Overall):
• Operating Temperature Range: -20°C To +125°C
• Non-UL Temperature Rating: 125°C
• Bulk Cable Weight: 125 lbs/1000 ft.
• Max. Recommended Pulling Tension: 264 lbs.
• Min. Bend Radius/Minor Axis: 4 in.
Applicable Specifications and Agency Compliance (Overall):
Applicable Standards & Environmental Programs:
• NEC/(UL) Specification: CMP
• CEC/C(UL) Specification: CMP
• EU Directive 2011/65/EU (ROHS II): Yes
• EU CE Mark: No
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 04/01/2005
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire & Cable): Yes
• MII Order #39 (China RoHS): Yes
• RG Type: Sub-miniature 11/U
Electrical Characteristics (Overall):
• Nom. Characteristic Impedance (Ohm): 75
• Nom. Inductance (μH/ft): 0.108
• Nom. Capacitance Conductor to Shield (pF/ft): 16.5
• Nominal Velocity of Propagation VP (%): 80
• Nominal Delay (ns/ft): 1.27
• Nom. Conductor DCR @ 20°C (Ohm/1000 ft): 3.1
• Nom. Inner Shield DCR @ 20°C (Ohm/1000 ft): 1.250
• Nominal outer Shield DCR @ 20°C (Ohm/1000 ft): 1.300
• Max.Operating Voltage - UL: 300 V RMS
• Sweep Testing: 100% sweep tested 5 MHz to 4500 MHz.
Flame Test:
• UL Flame Test: NFPA 262
Suitability:
• Suitability - Indoor: Yes
• Suitability - Outdoor: Yes
• Suitability - Burial: Yes
Plenum/Non-Plenum:
• Plenum (Y/N): Yes
Benefits and Features:
• Direct burial, riser and plenum options for permanent installations
• Flexible versions available for portable applications
• Multiple jacket options: Belflex for extra flexibility (available in up to 6 different colors) or SCPE thermoset jacket for more rugged applications
technical specification: | |
awg | 15 |
# coax | 1 |
stranding | solid |
number of conductors | 1 |
conductor material | bare copper |
dia. (in.) | 0.064 |
outer shield - type | braid |
outer shield - material | bare copper |
overall cable - nominal dia. (in.) | 0.406 |
belden cable part number | 1859A |