Belden 21600 10 AWG 2 Conductors 600V Type TC/CIC Cable
Select gauge from drop-down menu for prices:
- Belden 10 AWG Multi Conductor Unshielded CSA Control and Power Cable 600V TC/CIC
- Belden 21601 10 AWG 3 Conductors 600V Type TC/CIC Cable
- Belden 21602 10 AWG 4 Conductors 600V Type TC/CIC Cable
- Belden 21603 10 AWG 5 Conductors 600V Type TC/CIC Cable
- Belden 21604 10 AWG 6 Conductors 600V Type TC/CIC Cable
- Belden 21605 10 AWG 7 Conductors 600V Type TC/CIC Cable
- Belden 21606 10 AWG 8 Conductors 600V Type TC/CIC Cable
- Belden 21607 10 AWG 9 Conductors 600V Type TC/CIC Cable
- Belden 21608 10 AWG 10 Conductors 600V Type TC/CIC Cable
- Belden 21609 10 AWG 11 Conductors 600V Type TC/CIC Cable
- Belden 21610 10 AWG 12 Conductors 600V Type TC/CIC Cable
- Belden 21611 10 AWG 13 Conductors 600V Type TC/CIC Cable
- Belden 21612 10 AWG 14 Conductors 600V Type TC/CIC Cable
- Belden 21613 10 AWG 15 Conductors 600V Type TC/CIC Cable
- Belden 21614 10 AWG 16 Conductors 600V Type TC/CIC Cable
- Belden 21615 10 AWG 17 Conductors 600V Type TC/CIC Cable
- Belden 21616 10 AWG 18 Conductors 600V Type TC/CIC Cable
- Belden 21617 10 AWG 19 Conductors 600V Type TC/CIC Cable
- Belden 21618 10 AWG 20 Conductors 600V Type TC/CIC Cable
- Belden 21619 10 AWG 21 Conductors 600V Type TC/CIC Cable
- Belden 21620 10 AWG 22 Conductors 600V Type TC/CIC Cable
- Belden 21621 10 AWG 23 Conductors 600V Type TC/CIC Cable
- Belden 21622 10 AWG 24 Conductors 600V Type TC/CIC Cable
- Belden 21623 10 AWG 25 Conductors 600V Type TC/CIC Cable
- Belden 21624 10 AWG 26 Conductors 600V Type TC/CIC Cable
- Belden 21625 10 AWG 27 Conductors 600V Type TC/CIC Cable
- Belden 21626 10 AWG 28 Conductors 600V Type TC/CIC Cable
- Belden 21627 10 AWG 29 Conductors 600V Type TC/CIC Cable
- Belden 21628 10 AWG 30 Conductors 600V Type TC/CIC Cable
- Belden 21629 10 AWG 31 Conductors 600V Type TC/CIC Cable
- Belden 21630 10 AWG 32 Conductors 600V Type TC/CIC Cable
- Belden 21631 10 AWG 33 Conductors 600V Type TC/CIC Cable
- Belden 21632 10 AWG 34 Conductors 600V Type TC/CIC Cable
- Belden 21633 10 AWG 35 Conductors 600V Type TC/CIC Cable
- Belden 21634 10 AWG 36 Conductors 600V Type TC/CIC Cable
- Belden 21635 10 AWG 37 Conductors 600V Type TC/CIC Cable
- Belden 21636 10 AWG 38 Conductors 600V Type TC/CIC Cable
- Belden 21637 10 AWG 39 Conductors 600V Type TC/CIC Cable
- Belden 21638 10 AWG 40 Conductors 600V Type TC/CIC Cable
- Belden 21639 10 AWG 41 Conductors 600V Type TC/CIC Cable
- Belden 21640 10 AWG 42 Conductors 600V Type TC/CIC Cable
- Belden 21641 10 AWG 43 Conductors 600V Type TC/CIC Cable
- Belden 21642 10 AWG 44 Conductors 600V Type TC/CIC Cable
- Belden 21643 10 AWG 45 Conductors 600V Type TC/CIC Cable
- Belden 21644 10 AWG 46 Conductors 600V Type TC/CIC Cable
- Belden 21645 10 AWG 47 Conductors 600V Type TC/CIC Cable
- Belden 21646 10 AWG 48 Conductors 600V Type TC/CIC Cable
- Belden 21647 10 AWG 49 Conductors 600V Type TC/CIC Cable
- Belden 21648 10 AWG 50 Conductors 600V Type TC/CIC Cable
Description:
• 10 AWG stranded (7x18) bare copper conductors, separator tape, FR-XLPE insulation, 12 AWG Insulated Green Bare Copper Ground Wire,FR-PVC jacket.
Ground Wire:
• Ground Wire (Y/N): Y
• AWG: 12
• Stranding: 7x20
• Conductor Material: BC - Bare Copper
• Insulation Material: XLPE - Cross Linked Polyethylene
Insulation:
• Material: FR-XLPE - Cross Linked Polyethylene
Outer Jacket:
• Material: FR-PVC - Polyvinyl Chloride
• Outer Jacket Ripcord: Yes
Mechanical Charactertistics (Overall):
• Installation Temperature Range: -25°C To +90°C
• Operating Temperature Range: -40°C To +90°C
• Non-UL Temperature Rating: 90°C
• Bulk Cable Weight: 194.954 Kg/Km
• Max. Recommended Pulling Tension: 1334.460 N
• Min. Bend Radius/Minor Axis: 121.920 mm
Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• CSA Specification: C22.2 #230 Type TC; C22.2#239 Type CIC
• EU Directive 2011/65/EU (ROHS II): Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 05/24/2006
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes
Electrical Characteristics (Overall):
• Nom. Conductor DC Resistance @ 20°C (Ohm/km): 3.24163
• Max. Operating Voltage - Non-UL: 600 (CSA TC)
Flame Test:
• CSA Flame Test: FT4
Suitability:
• Suitability - Indoor: Yes
• Suitability - Outdoor: Yes
• Sunlight Resistance: Yes
Plenum/Non-Plenum:
• Plenum (Y/N): No
technical specification: | |
awg | 10 |
# conductors | 2 |
stranding | 7x18 |
conductor material | bare copper |
outer shield - material | unshielded |
overall cable- nominal dia. (mm) | 12.192 |
belden cable part number | 21600 |