Belden 25504 16 AWG 1 Pair 600V ACIC Armored Multi Conductor Steel Cable
Select gauge from drop-down menu for prices:
- Belden 16 AWG CSA Instrumentation 600V ACIC Armored Individually and Overall Beldfoil Shielded Pairs 7x24 Cable
- Belden 25510 16 AWG 2 Pairs 600V ACIC Armored Multi Conductor Steel Cable
- Belden 25511 16 AWG 4 Pairs 600V ACIC Armored Multi Conductor Steel Cable
- Belden 25512 16 AWG 6 Pairs 600V ACIC Armored Multi Conductor Steel Cable
- Belden 25513 16 AWG 8 Pairs 600V ACIC Armored Multi Conductor Steel Cable
- Belden 25518 16 AWG 12 Pairs 600V ACIC Armored Multi Conductor Steel Cable
- Belden 25519 16 AWG 24 Pairs 600V ACIC Armored Multi Conductor Steel Cable
- Belden 24500 16 AWG 1 Pair 600V ACIC Armored Multi Conductor Aluminum Cable
- Belden 24505 16 AWG 2 Pairs 600V ACIC Armored Multi Conductor Aluminum Cable
- Belden 24502 16 AWG 4 Pairs 600V ACIC Armored Multi Conductor Aluminum Cable
- Belden 24506 16 AWG 6 Pairs 600V ACIC Armored Multi Conductor Aluminum Cable
- Belden 24503 16 AWG 8 Pairs 600V ACIC Armored Multi Conductor Aluminum Cable
- Belden 24504 16 AWG 12 Pairs 600V ACIC Armored Multi Conductor Aluminum Cable
- Belden 24510 16 AWG 24 Pairs 600V ACIC Armored Multi Conductor Aluminum Cable
Product Details
Description:
• 16 AWG pairs stranded (7x24) tinned copper conductors, individual Beldfoil® plus a polyester isolation tape, PVC insulation, PVC inner jacket, overall Beldfoil shield (100% coverage), interlocked armor, PVC outer jacket.
Insulation:
• Material: PVC - Polyvinyl Chloride
• Wall Thickness (mm): 0.762
Inner Jacket:
• Material: PVC - Polyvinyl Chloride
• Nom. Dia. (mm): 8.636
• Inner Jacket Ripcord: Yes
Outer Shield Drain Wire AWG:
• AWG: 18
• Stranding: 7x26
• Material: TC - Tinned Copper
Outer Jacket:
• Material: PVC - Polyvinyl Chloride
• Nom. Dia. (mm): 16.256
• Outer Jacket Ripcord: Yes
Armor:
• Armor Type: Interlocked
• Armor Material: Steel
Overall Cable:
• Separator Material: Polyester
Mechanical Charactertistics (Overall):
• Installation Temperature Range: -25°C To +105°C
• Wet Temperature Range: -40°C To +75°C
• Dry Temperature Range: -40°C To +105°C
• Bulk Cable Weight: 415.208 Kg/Km
• Max. Recommended Pulling Tension: 417.241 N
• Min. Bend Radius/Minor Axis: 195.580 mm
Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• CSA Specification: C22.2#239, Type ACIC, C22.2#174, HLABCD, C22.2#0.3, Clause 4.31 Low Acid Test
• EU Directive 2011/65/EU (ROHS II): Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 01/01/2006
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes
• Other Specification: Low Acid Test
Electrical Characteristics (Overall):
• Nom. Conductor DC Resistance @ 20°C (Ohm/km): 13.7802 (16 AWG)
• Nom. Conductor DC Resistance @ 20°C (Ohm/km): 48.2307 (22 AWG)
• Ind. Pair Nominal Shield DC Resistance @ 20 Deg. C: 21.983 Ohm/km
• Max. Operating Voltage - Other: 600 (CEC ACIC)
Flame Test:
• CSA Flame Test: FT4
Suitability:
• Sunlight Resistance: Yes
Plenum/Non-Plenum:
• Plenum (Y/N): No
technical specification: | |
awg | 16 |
# pairs | 1 |
stranding | 7x24 |
no. of conductors | 2 |
conductor material | tinned copper |
outer shield - type | tape |
outer shield - material | aluminum foil-polyester tape |
overall cable- nominal dia. (mm) | 16.256 |
belden cable part number - steel | 25504 |