Belden 25506 18 AWG 1 Pair 600V ACIC Armored Multi Conductor Steel Cable

Belden 25506 18 AWG 1 Pair 600V ACIC Armored Multi Conductor Steel Cable

Belden 25506 18 AWG 1 Pair 600V ACIC Armored Multi Conductor Steel Cable

Description:
• 18 AWG pairs stranded (7x26) tinned copper conductors, individual Beldfoil® plus a polyester isolation tape, PVC insulation, PVC inner jacket, overall Beldfoil shield (100% coverage), interlocked armor, PVC outer jacket.

Insulation:
• Material: PVC - Polyvinyl Chloride
• Wall Thickness (mm): 0.762

Inner Jacket:
• Material: PVC - Polyvinyl Chloride
• Nom. Dia. (mm): 8.128
• Inner Jacket Ripcord: Yes

Outer Shield Drain Wire AWG:
• AWG: 20
• Stranding: 7x28
• Material: TC - Tinned Copper

Outer Jacket:
• Material: PVC - Polyvinyl Chloride
• Nom. Dia. (mm): 15.494
• Outer Jacket Ripcord: Yes

Armor:
• Armor Type: Interlocked
• Armor Material: Steel

Mechanical Charactertistics (Overall):
• Installation Temperature Range: -25°C To +105°C
• Wet Temperature Range: -40°C To +75°C
• Dry Temperature Range: -40°C To +105°C
• Bulk Cable Weight: 382.467 Kg/Km
• Max. Recommended Pulling Tension: 255.327 N
• Min. Bend Radius/Minor Axis: 185.420 mm

Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• CSA Specification: C22.2#239, Type ACIC, C22.2#174, HLABCD, C22.2#0.3, Clause 4.31 Low Acid Test
• EU Directive 2011/65/EU (ROHS II): Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 01/01/2006
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes
• Other Specification: Low Acid Test

Electrical Characteristics (Overall):
• Nom. Conductor DC Resistance @ 20°C (Ohm/km): 19.2267 (18 AWG)
• Nom. Conductor DC Resistance @ 20°C (Ohm/km): 48.2307 (22 AWG)
• Nominal Outer Shield DC Resistance @ 20°C (Ohm/km): 14.1083
• Ind. Pair Nominal Shield DC Resistance @ 20 Deg. C: 33.794 Ohm/km
• Max. Operating Voltage - Other: 600 (CEC ACIC)
• Max. Recommended Current: 2.5 Amps/Conductor @ 25°C

Flame Test:
• CSA Flame Test: FT4

Plenum/Non-Plenum:
• Plenum (Y/N): No

technical specification:
awg 18
# pairs 1
stranding 7x26
no. of conductors 2
conductor material tinned copper
outer shield - type tape
outer shield - material aluminum foil-polyester tape
overall cable- nominal dia. (mm) 15.494
belden cable part number - steel 25506

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.

Ask a Question