Belden 28293 6 AWG 2 Conductors 600V Type MC Metal Clad Steel Cable
Select gauge from drop-down menu for prices:
- Belden 6 AWG Interlocked Armor Uninsulated Ground Wire UL Control 600V Type MC Metal Clad Cable
- Belden 27293 6 AWG 2 Conductors 600V Type MC Metal Clad Aluminum Cable
- Belden 27262 6 AWG 3 Conductors 600V Type MC Metal Clad Aluminum Cable
- Belden 27263 6 AWG 4 Conductors 600V Type MC Metal Clad Aluminum Cable
- Belden 28262 6 AWG 3 Conductors 600V Type MC Metal Clad Steel Cable
- Belden 28263 6 AWG 4 Conductors 600V Type MC Metal Clad Steel Cable
Description:
• 6 AWG stranded (7x14) bare copper conductors, 8 AWG bare copper ground wire, cross-linked polyethylene insulation, steel interlocked
armor, PVC jacket.
Ground Wire:
• Ground Wire (Y/N): Y
• Ground Wire AWG: 8
• Ground Wire Stranding: 7x16
• Ground Wire Conductor Material: BC - Bare Copper
Insulation:
• Material: XLPE - Cross Linked Polyethylene
• Wall Thickness (mm): 1.143
Outer Jacket:
• Outer Jacket over Armor (y/n): Y
Outer Jacket over Armor:
• Outer Jacket Material over Armor (y/n): PVC
• Outer Jacket Wall Thickness Over Armor: 0.050
Armor:
• Armor Type: Interlocked
• Armor Material: steel
• Diameter over Armor: 0.760
Mechanical Charactertistics (Overall):
• Operating Temperature Range: -40°C To +90°C
• Wet Temperature Range: -40°C To +90°C
• Dry Temperature Range: -40°C To +90°C
• Bulk Cable Weight: 642.902 Kg/Km
• Max. Recommended Pulling Tension: 1868.240 N
• Min. Bend Radius/Minor Axis: 271.780 mm
Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• NEC/(UL) Specification: MC, XHHW-2 Singles, UL1569
• EU Directive 2011/65/EU (ROHS II): Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 10/13/2005
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes
Electrical Characteristics (Overall):
• Nom. Conductor DC Resistance @ 20°C (Ohm/km): 1.34521
• Max. Operating Voltage - UL: 600 V RMS
• Max. Recommended Current: 75 Amps/conductor @ 25°C
Flame Test:
• UL Flame Test: VW-1 Singles, UL1685 UL Loading
Suitability:
• Suitability - Burial: Yes
• Sunlight Resistance: Yes
Plenum/Non-Plenum:
• Plenum (Y/N): No
technical specification: | |
awg | 6 |
# conductors | 2 |
stranding | 7x14 |
no. of conductors | 2 |
conductor material | bare copper |
outer shield - material | unshielded |
overall cable- nominal dia. (mm) | 22.098 |
belden cable part number - steel | 28293 |