Belden 29557C Cable 1 AWG with Dual Copper Tape Shield CSA VFD Cable
Select gauge from drop-down menu for prices:
- Belden Cable 14 to 4/0 AWG with Dual Copper Tape Shield CSA VFD Cable
- Belden 29550C Cable 14 AWG with Dual Copper Tape Shield CSA VFD Cable
- Belden 29551C Cable 12 AWG with Dual Copper Tape Shield CSA VFD Cable
- Belden 29552C Cable 10 AWG with Dual Copper Tape Shield CSA VFD Cable
- Belden 29553C Cable 8 AWG with Dual Copper Tape Shield CSA VFD Cable
- Belden 29554C Cable 6 AWG with Dual Copper Tape Shield CSA VFD Cable
- Belden 29555C Cable 4 AWG with Dual Copper Tape Shield CSA VFD Cable
- Belden 29556C Cable 2 AWG with Dual Copper Tape Shield CSA VFD Cable
- Belden 29558C Cable 1/0 AWG with Dual Copper Tape Shield CSA VFD Cable
- Belden 29559C Cable 2/0 AWG with Dual Copper Tape Shield CSA VFD Cable
- Belden 29560C Cable 3/0 AWG with Dual Copper Tape Shield CSA VFD Cable
- Belden 29561C Cable 4/0 AWG with Dual Copper Tape Shield CSA VFD Cable
Features:
• Thicker, industrial-grade XLPE insulations provide low capacitance for extended motor life, reduced likelihood of corona discharge, reduced magnitude of standing waves, increased efficiency of power transfer
• Robust ground and shielding system to minimize radiated and conducted noise that can disrupt plant control and instrumentation systems
• Reliably carry power from AC drive systems to AC motors
• Effectively handle the overall high power levels of pulse-width modulated (PWM) signals
• Reliably handle high voltage spikes – eliminating potential damage to the cable, motors, bearings, drives and related equipment - potentially extending their life
• Industrial-grade PVC jackets provide sunlight- and oil-resistance; Haloarrest jackets are halogen-free and provide sunlight-resistance in LSZH versions
• Impervious to adverse or harsh environments
• ER rating allows for the elimination of conduit for easier and less expensive installations
• Effectively eliminate downtime due to cable failure
Technical Data:
• 1000V CSA TC
• CSA C22. 2 #230
• CSA C22.2 #38
• CSA FT-4
• IEEE 1202
• Direct Burial
• RW90 Rated Circuit Conductors
• 90°C Wet/Dry
• XLP Insulation
• Sunlight and Oil Resistant
• Black PVC Jacket
• RoHS Compliant
Benefits:
• Superior protection against electrical noise
• Increased stability in electrical performance
• Improved system uptime in harsh environments
technical specifications: | |
awg | 1 |
cond. stranding | 19 x 14 |
standard lengths(ft) | 1000 |
standard lengths(m) | 304.8 |
standard unit wt(lbs.) | 1193 |
standard unit wt(kg) | 541.1 |
nominal od(inch) | 1.13 |
nominal od(mm) | 28.70 |
maximum pull tension(lbs.) | 2650 |
maximum pull tension(n) | 1202 |
minimum bend radius(inch) | 11.5 |
minimum bend radius(mm) | 292.1 |
belden cable part number | 29557C |