Belden 3001A 22 AWG 2 Pairs 300V PLTC Multi Conductor Cable
Select gauge from drop-down menu for prices:
- Belden 22 AWG 300V PLTC Individually and Overall Beldfoil Shielding Orange Communication Cable
- Belden 3005A 22 AWG 4 Pairs 300V PLTC Multi Conductor Cable
- Belden 3007A 22 AWG 8 Pairs 300V PLTC Multi Conductor Cable
- Belden 3009A 22 AWG 12 Pairs 300V PLTC Multi Conductor Cable
- Belden 3011A 22 AWG 16 Pairs 300V PLTC Multi Conductor Cable
- Belden 3013A 22 AWG 24 Pairs 300V PLTC Multi Conductor Cable
- Belden 3015A 22 AWG 50 Pairs 300V PLTC Multi Conductor Cable
Description: 22 AWG pairs stranded (7x30) bare copper conductors, twisted pairs, PVC insulation, individually shielded plus an overall Beldfoil® shield (100% coverage), PVC jacket.
Insulation:
• Material: PVC - Polyvinyl Chloride
• Dia. (mm): 1.5748
Inner Shield:
• Trame Name: Beldfoil®
• Type: Tape
• Material: Aluminum Foil-Polyester Tape
Inner Shield Drian Wire AWG:
• AWG: 22
• Stranding: 7x30
• Material: TC - Tinned Copper
Outer Shield Drian Wire AWG:
• AWG: 22
• Stranding: 7x30
• Material: TC - Tinned Copper
Outer Jacket:
• Material: PVC - Polyvinyl Chloride
• Nom. Wall Thickness (mm): 1.0668
• Outer Jacket Ripcord: Yes
Mechanical Charactertistics (Overall):
• Operating Temperature Range: -30°C To +105°C
• UL Temperature Rating: 105°C
• Bulk Cable Weight: 65.481 Kg/Km
• Max. Recommended Pulling Tension: 240.203 N
• Min. Bend Radius/Minor Axis: 82.550 mm
Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• NEC/(UL) Specification: CMG, ITC-ER, PLTC-ER
• CEC/C(UL) Specification: CMG
• EU Directive 2011/65/EU (ROHS II): Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 04/01/2005
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes
Surface Printing (Overall):
Electrical Characteristics (Overall):
• Nom. Inductance (?H/m): 0.68901
• Nom. Capacitance Conductor to Conductor (pF/m): 85.306
• Nom. Conductor DC Resistance @ 20°C (Ohm/km): 49.215
• Max. Operating Voltage - UL: 300 V RMS (PLTC CMG)
• Max. Operating Voltage - UL: 150 V RMS (ITC)
• Max. Recommended Current: 3.8 Amps/Conductor @ 25°C
Flame Test:
• UL Flame Test: UL1685 FT4 Loading
• C(UL) Flame Test: FT4
• IEEE Flame Test: 1202
Suitability:
• Suitability - Indoor: Yes
• Suitability - Outdoor: Yes
• Suitability - Burial: Yes
• Sunlight Resistance: Yes
Plenum/Non-Plenum:
• Plenum (Y/N): No
technical specification: | |
awg | 22 |
# pairs | 2 |
stranding | 7x30 |
no. of conductors | 5 |
conductor material | bare copper |
outer shield - type | tape |
outer shield - material | aluminum foil-polyester tape |
overall cable- nominal dia. (mm) | 8.230 |
belden cable part number | 3001A |