Belden 3633 Cable 23 AWG 4 Pairs Category 6 Bonded-Pair Enhanced Multi Conductor Solid Bare Copper Flamarrest PVC Jacket Cable

Belden 3633 Cable 23 AWG 4 Pairs Category 6 Bonded-Pair Enhanced Multi Conductor Solid Bare Copper Flamarrest PVC Jacket Cable

Select gauge from drop-down menu for prices:

Belden 3633 Cable 23 AWG 4 Pairs Category 6 Bonded-Pair Enhanced Multi Conductor Solid Bare Copper Flamarrest PVC Jacket Cable

Precio habitual $1.43 $0.95 Oferta /per Foot

Belden 3633 Cable 23 AWG 4 Pairs Category 6 Bonded-Pair Enhanced Multi Conductor Solid Bare Copper Flamarrest PVC Jacket Cable

Description:
• CAT6+ (400MHz), 4-Bonded-Pairs, U/UTP-Unshielded, Plenum-CMP, Premise Horizontal Cable, 23 AWG Solid Bare Copper Conductors, FEP Insulation, Patented X-Spline, Ripcord, Flamarrest® PVC jacket.

Insulation:
• Material: FEP - Fluorinated Ethylene Polyolefin

Outer Jacket:
• Trade Name: Flamarrest
• Material: LS PVC - Low Smoke Polyvinyl Chloride
• Nom. Wall Thickness (in.): 0.018
• Nom. Diameter (in.): 0.235
• Outer Jacket Ripcord: Yes

Usage (Overall):
Applications:
• Premise Horizontal Cable, Gigabit Ethernet, POE, POE+,100BaseTX, 100BaseVG ANYLAN, 155ATM, 622ATM, NTSC/PAL Component or Composite Video, AES/EBU Digital Audio, AES51, RS-422, Noisy Environments.

Mechanical Characteristics (Overall):
• Storage Temperature Range: -20°C To +75°C
• Installation Temperature Range: +5°C To +50°C
• Operating Temperature Range: 0°C To +75°C
• UL Temperature Rating: 75°C
• Bulk Cable Weight: 32 lbs/1000 ft.
• Max. Recommended Pulling Tension: 50 lbs.
• Min. Bend Radius/Minor Axis: 0.500 in.
• Min. Bend/Installation: 2 in.

Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• NEC/(UL) Specification: CMP
• CEC/C(UL) Specification: CMP
• EU Directive 2011/65/EU (ROHS II): Yes
• Other Standards: ISO/IEC 11801 ed 2.1 (2008) Class E
• EU CE Mark: Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 04/03/2009
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes
• Telecommunications Standards: Category 6 - TIA 568.C.2

Electrical Characteristics (Overall):
• Nom. Mutual Capacitance (pF/ft): 15.500
• Maximum Capacitance Unbalance (pF/100m): 90
• Nominal Velocity of Propagation: VP (%): 72.000
• Maximum Delay (ns/100 m): 537.600 @ 100MHz
• Typical Delay Skew (ns/ft): 30.000
• Maximum Conductor DC Resistance @ 20°C (Ohm/100 m): 7.700
• Max. Operating Voltage - UL: 300 V RMS
• Maximum DCR Unbalanced @ 20°C (%): 3.000

Flame Test:
• UL Flame Test: NFPA 262
• C(UL) Flame Test: FT6

Suitability:
• Suitability - Indoor: Yes
• Suitability - Outdoor: No
• Suitability - Aerial: No
• Suitability - Burial: No
• Sunlight Resistance: No

Plenum/Non-Plenum:
• Plenum(Y/N): Yes
• Non-Plenum Number: 3632

technical specification:
awg 23
# pairs 4
stranding solid
no. of conductors 8
conductor material bare copper
outer shield - type -
outer shield - material unshielded
overall cable - nominal diameter (in.) 0.235
belden cable part number 3633