Belden 601591 10 AWG 2 Conductors Spec 19-1 Solid Signal Cable
Select gauge from drop-down menu for prices:
- Belden IMSA Spec 19-1 Aerial and Duct 600V Signal Cable
- Belden 601455 14 AWG 2 Conductors Spec 19-1 Solid Signal Cable
- Belden 601457 14 AWG 2 Conductors Spec 19-1 Stranded Signal Cable
- Belden 601176 14 AWG 3 Conductors Spec 19-1 Solid Signal Cable
- Belden 601203 14 AWG 3 Conductors Spec 19-1 Stranded Signal Cable
- Belden 601321 14 AWG 4 Conductors Spec 19-1 Solid Signal Cable
- Belden 601137 14 AWG 4 Conductors Spec 19-1 Stranded Signal Cable
- Belden 601177 14 AWG 5 Conductors Spec 19-1 Solid Signal Cable
- Belden 601204 14 AWG 5 Conductors Spec 19-1 Stranded Signal Cable
- Belden 601179 14 AWG 7 Conductors Spec 19-1 Solid Signal Cable
- Belden 601205 14 AWG 7 Conductors Spec 19-1 Stranded Signal Cable
- Belden 601180 14 AWG 9 Conductors Spec 19-1 Solid Signal Cable
- Belden 601352 14 AWG 9 Conductors Spec 19-1 Stranded Signal Cable
- Belden 601181 14 AWG 10 Conductors Spec 19-1 Solid Signal Cable
- Belden 601206 14 AWG 10 Conductors Spec 19-1 Stranded Signal Cable
- Belden 601948 14 AWG 11 Conductors Spec 19-1 Stranded Signal Cable
- Belden 601182 14 AWG 12 Conductors Spec 19-1 Solid Signal Cable
- Belden 601207 14 AWG 12 Conductors Spec 19-1 Stranded Signal Cable
- Belden 601208 14 AWG 14 Conductors Spec 19-1 Stranded Signal Cable
- Belden 601671 14 AWG 15 Conductors Spec 19-1 Solid Signal Cable
- Belden 601539 14 AWG 15 Conductors Spec 19-1 Stranded Signal Cable
- Belden 601415 14 AWG 16 Conductors Spec 19-1 Solid Signal Cable
- Belden 601320 14 AWG 16 Conductors Spec 19-1 Stranded Signal Cable
- Belden 601826 14 AWG 19 Conductors Spec 19-1 Solid Signal Cable
- Belden 601480 14 AWG 19 Conductors Spec 19-1 Stranded Signal Cable
- Belden 601633 14 AWG 20 Conductors Spec 19-1 Solid Signal Cable
- Belden 601443 14 AWG 20 Conductors Spec 19-1 Stranded Signal Cable
- Belden 601209 14 AWG 21 Conductors Spec 19-1 Stranded Signal Cable
- Belden 601534 14 AWG 25 Conductors Spec 19-1 Solid Signal Cable
- Belden 601890 14 AWG 25 Conductors Spec 19-1 Stranded Signal Cable
- Belden 601334 12 AWG 2 Conductors Spec 19-1 Solid Signal Cable
- Belden 601448 12 AWG 2 Conductors Spec 19-1 Stranded Signal Cable
- Belden 601456 12 AWG 3 Conductors Spec 19-1 Solid Signal Cable
- Belden 601431 12 AWG 3 Conductors Spec 19-1 Stranded Signal Cable
- Belden 601189 12 AWG 4 Conductors Spec 19-1 Solid Signal Cable
- Belden 601466 12 AWG 4 Conductors Spec 19-1 Stranded Signal Cable
- Belden 601190 12 AWG 5 Conductors Spec 19-1 Solid Signal Cable
- Belden 601410 12 AWG 5 Conductors Spec 19-1 Stranded Signal Cable
- Belden 601192 12 AWG 7 Conductors Spec 19-1 Solid Signal Cable
- Belden 601213 12 AWG 7 Conductors Spec 19-1 Stranded Signal Cable
- Belden 601193 12 AWG 9 Conductors Spec 19-1 Solid Signal Cable
- Belden 601468 12 AWG 9 Conductors Spec 19-1 Stranded Signal Cable
- Belden 601930 12 AWG 10 Conductors Spec 19-1 Stranded Signal Cable
- Belden 601496 12 AWG 12 Conductors Spec 19-1 Solid Signal Cable
- Belden 601214 12 AWG 12 Conductors Spec 19-1 Stranded Signal Cable
- Belden 601358 12 AWG 16 Conductors Spec 19-1 Solid Signal Cable
- Belden 518719 12 AWG 19 Conductors Spec 19-1 Stranded Signal Cable
- Belden 601578 12 AWG 20 Conductors Spec 19-1 Solid Signal Cable
- Belden 603061 10 AWG 2 Conductors Spec 19-1 Stranded Signal Cable
- Belden 601570 10 AWG 3 Conductors Spec 19-1 Solid Signal Cable
- Belden 603314 10 AWG 3 Conductors Spec 19-1 Stranded Signal Cable
- Belden 581665 10 AWG 4 Conductors Spec 19-1 Stranded Signal Cable
- Belden 580314 10 AWG 5 Conductors Spec 19-1 Stranded Signal Cable
Description:
• 10 AWG solid bare copper conductors, HDPE insulation, PVC jacket.
Ground Wire:
• Ground Wire (Y/N): N
Insulation:
• Material: HDPE - High Density Polyethylene
• Wall Thickness (mm): 0.762
Outer Jacket:
• Material: PVC - Polyvinyl Chloride
• Nom. Wall Thickness (mm): 1.143
Mechanical Charactertistics (Overall):
• Operating Temperature Range: -30°C To +80°C
• Bulk Cable Weight: 110 lbs/1000 ft.
• Max. Recommended Pulling Tension: 250 lbs.
• Min. Bend Radius/Minor Axis: 4.200 in.
Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• EU Directive 2011/65/EU (ROHS II): Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 10/01/2005
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes
• IMSA Specification: 19-1
Electrical Characteristics (Overall):
• Nom. Conductor DC Resistance @ 20°C (Ohm/1000 ft): 1.02
Suitability:
• Suitability - Outdoor: Yes
• Suitability - Aerial: Yes
Plenum/Non-Plenum:
• Plenum (Y/N): No
technical specification: | |
awg | 10 |
# conductors | 2 |
solid or stranded | solid |
no. of conductors | 2 |
conductor material | bare copper |
outer shield - material | unshielded |
overall cable- nominal dia. (mm) | 10.693 |
belden cable part number | 601591 |