Belden 8770 18 AWG 3C Beldfoil Shield Instrumentation Cable
Select gauge from drop-down menu for prices:
- Belden Cable 18 AWG Audio Control and Instrumentation Overall Beldfoil Shield Non Plenum Cable
- Belden 9418 Cable 18 AWG 4 Conductors Audio Control and Instrumentation Overall Beldfoil Shield Non Plenum Cable
- Belden 88770 Cable 18 AWG 3 Conductors Audio Control and Instrumentation Overall Beldfoil Shield FEP Jacket Cable
- Belden 89418 Cable 18 AWG 4 Conductors Audio Control and Instrumentation Overall Beldfoil Shield FEP Jacket Cable
- Belden 82418 Cable 18 AWG 4 Conductors Audio Control and Instrumentation Overall Beldfoil Shield Flamarrest Jacket Cable
Description:
• 18 AWG stranded (16x30) tinned copper conductors, conductors cabled, polyethylene insulation, overall Beldfoil® shield (100% coverage), 20 AWG stranded tinned copper drain wire, PVC jacket.
Insulation:
• Material: PE - Polyethylene
• Wall Thickness (mm): 0.4572
Outer Shield Drain Wire AWG:
• AWG: 20
• Stranding: Stranded
• Material: TC - Tinned Copper
Outer Jacket:
• Material: PVC - Polyvinyl Chloride
• Nom. Wall Thickness (mm): 0.8382
Overall Cabling Lay Length and Direction:
• Length (in.): 2.700
• Twists (twist/ft): 4.400 (Left Hand Direction)
Mechanical Charactertistics (Overall):
• Operating Temperature Range: -20°C To +60°C
• UL Temperature Rating: 60°C (UL AWM Style 2093)
• Bulk Cable Weight: 36 lbs/1000 ft.
• Max. Recommended Pulling Tension: 74 lbs.
• Min. Bend Radius/Minor Axis: 2.500 in.
Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• NEC/(UL) Specification: CM
• NEC Articles: 800
• CEC/C(UL) Specification: CM
• AWM Specification: UL Style 2093 (300 V 60°C)
• EU Directive 2011/65/EU (ROHS II): Yes
• EU CE Mark: Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 01/01/2004
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes
Electrical Characteristics (Overall):
• Nom. Characteristic Impedance (Ohm): 69
• Nom. Inductance (μH/ft): 0.180
• Nom. Capacitance Conductor to Conductor (pF/ft): 24
• Nom. Capacitance Cond. to Other Conductor & Shield (pF/ft): 48
• Nom. Conductor DC Resistance @ 20°C (Ohm/1000 ft): 6.6
• Nominal Outer Shield DC Resistance @ 20°C (Ohm/1000 ft): 8.5
• Max. Operating Voltage - UL: 300 V RMS
• Max. Recommended Current: 5.3 Amps/Conductor @ 25°C ambient (10C Temp. Rise)
Flame Test:
• UL Flame Test: UL1685 UL Loading
• CSA Flame Test: FT1
Suitability:
• Suitability - Indoor: Yes
Plenum/Non-Plenum:
• Plenum (Y/N): No
• Plenum Number: 88770
Belden 8770 Technical Specification: | |
AWG | 18 |
# conductors | 3 |
stranding | 16x30 |
no. of conductors | 3 |
conductor material | tinned copper |
outer shield - type | tape |
outer shield - material | aluminum foil-polyester tape w/shorting fold |
overall cable- nominal dia. (mm) | 6.2484 |
belden cable part number | 8770 |