Belden 8786 Cable 24 and 22 AWG Special Audio Communication and Instrumentation Overall Shield PVC Jacket Cable

Belden 8786 Cable 24 and 22 AWG Special Audio Communication and Instrumentation Overall Shield PVC Jacket Cable

Precio habitual $4.70 $3.46 Oferta /per Foot

Belden 8786 Cable 24 and 22 AWG Special Audio Communication and Instrumentation Overall Shield PVC Jacket Cable

Description:
• 24 and 22 AWG stranded (7x32 and 7x30)) TC conductors, PVC insulation, (4) conductors cabled, 22 AWG stranded TC drain wire, PVC jacket.

Insulation:
• Material: PVC - Polyvinyl Chloride
• Wall Thickness (mm): 0.381
• Insulation Resistance: 100 Megaohms/1000 ft. @ 500 V DC

Inner Shield Drain Wire AWG:
• AWG: 22
• Stranding: 7x30
• Material: TC - Tinned Copper

Outer Jacket:
• Material: PVC - Polyvinyl Chloride
• Nom. Wall Thickness (mm): 0.7112

Mechanical Charactertistics (Overall):
• Operating Temperature Range: -20°C To +80°C
• Non-UL Temperature Rating: 90°C
• Bulk Cable Weight: 44.646 Kg/Km
• Max. Recommended Pulling Tension: 178.818 N
• Min. Bend Radius/Minor Axis: 63.500 mm

Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• NEC/(UL) Specification: CM
• NEC Articles: 800
• EU Directive 2011/65/EU (ROHS II): Yes
• EU CE Mark: Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 04/01/2005
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes

Electrical Characteristics (Overall):
• Nom. Cap. Between Cond. in a Quad Config (pF/m): 65.62
• Nominal Velocity of Propagation (VP %): 65
• Nom. Conductor DC Resistance @ 20°C (Ohm/km): 78.4159 (24 AWG)
• Nom. Conductor DC Resistance @ 20°C (Ohm/km): 49.215 (22 AWG)
• Nom. Inner Shield DC Resistance @ 20°C (Ohm/km): 39.0439 (24 AWG Quad)
• Max. Operating Voltage - UL: 300 V RMS
• Max. Recommended Current: 1.5 Amps/Conductor @ 25°C (24 AWG)
• Max. Recommended Current: 2.0 Amps/Conductor @ 25°C (22 AWG)

Flame Test:
• UL Flame Test: UL1685 UL Loading

Plenum/Non-Plenum:
• Plenum (Y/N): No

technical specification:
awg 24 and 22
# conductors 4 and 2
stranding 7x32 and 7x30
no. of conductors 6
conductor material tinned copper
inner shield - type tape
inner shield - material aluminum foil-polyester tape
overall cable- nominal dia. (mm) 5.994
belden cable part number 8786

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.

Ask a Question