Belden 9462 Cable 22 AWG 1 Pair Overall Beldfoil Shield Audio Control and Instrumentation Stranded 7x30 PVC Insulation Cable
Select gauge from drop-down menu for prices:
- Belden Cable Overall Beldfoil Shield Audio Control and Instrumentation Stranded Multi Conductor Paired Cable
- Belden 9414 Cable 22 AWG 1 Pair Overall Beldfoil Shield Audio Control and Instrumentation Stranded 7x30 PVC Jacket Cable
- Belden 8761 Cable 22 AWG 1 Pair Overall Beldfoil Shield Audio Control and Instrumentation Stranded 7x30 Polylethylene Insulation Cable
- Belden 9461 Cable 22 AWG 1 Pair Overall Beldfoil Shield Audio Control and Instrumentation Stranded 7x30 TC PVC Jacket Cable
- Belden 8719 Cable 16 AWG 1 Pair Overall Beldfoil Shield Audio Control and Instrumentation Stranded 19x29 PVC Jacket Cable
- Belden 8720 Cable 14 AWG 1 Pair Overall Beldfoil Shield Audio Control and Instrumentation Stranded 19x27 PVC Jacket Cable
- Belden 8718 Cable 12 AWG 1 Pair Overall Beldfoil Shield Audio Control and Instrumentation Stranded 19x25 PVC Jacket Cable
Description:
• 22 AWG stranded (7x30) tinned copper conductors, PVC insulation, twisted pair, overall Beldfoil® shield (100% coverage), 22 AWG stranded TC drain wire, PVC jacket.
Insulation:
• Material: PVC - Polyvinyl Chloride
• Wall Thickness (mm): 0.356
Outer Shield Drain Wire AWG:
• AWG: 22
• Stranding: 7x30
• Material: TC - Tinned Copper
Outer Jacket:
• Material: PVC - Polyvinyl Chloride
• Nom. Wall Thickness (mm): 0.889
Mechanical Charactertistics (Overall):
• Operating Temperature Range: -20°C To +80°C
• UL Temperature Rating: 80°C (UL AWM Style 2464)
• Bulk Cable Weight: 28.276 Kg/Km
• Max. Recommended Pulling Tension: 120.101 N
• Min. Bend Radius/Minor Axis: 50.800 mm
Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• NEC/(UL) Specification: CMG
• CEC/C(UL) Specification: CMG
• AWM Specification: UL Style 2464 (300 V 80°C)
• EU Directive 2011/65/EU (ROHS II): Yes
• EU CE Mark: Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 04/01/2005
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes
Electrical Characteristics (Overall):
• Nom. Characteristic Impedance (Ohm): 36
• Nom. Inductance (μH/m): 0.62339
• Nom. Capacitance Conductor to Conductor (pF/m): 164.05
• Nom. Capacitance Cond. to Other Conductor & Shield (pF/m): 295.29
• Nom. Conductor DC Resistance @ 20°C (Ohm/km): 52.496
• Max. Operating Voltage - UL: 300 V RMS
• Max. Recommended Current: 3 Amps/Conductor @ 25°C
Flame Test:
• UL Flame Test: UL1685 FT4 Loading
• CSA Flame Test: FT4
Plenum/Non-Plenum:
• Plenum (Y/N): No
technical specification: | |
awg | 22 |
# pairs | 1 |
stranding | 7x30 |
no. of conductors | 2 |
conductor material | tinned copper |
outer shield - type | tape |
outer shield - material | aluminum foil-polyester tape |
overall cable- nominal dia. (mm) | 4.724 |
belden cable part number | 9462 |