Belden 9498 Cable 16 AWG 3 Conductors Audio Control and Instrumentation Multi Conductor Stranded 19x29 Non Plenum Cable
Select gauge from drop-down menu for prices:
- Belden Cable 16 AWG Audio Control and Instrumentation Multi Conductor UnShielded Non Plenum Cable
- Belden 8620 Cable 16 AWG 4 Conductors Audio Control and Instrumentation Multi Conductor Stranded 19x29 Non Plenum Cable
- Belden 9620 Cable 16 AWG 5 Conductors Audio Control and Instrumentation Multi Conductor Stranded 19x29 Non Plenum Cable
- Belden 8621 Cable 16 AWG 7 Conductors Audio Control and Instrumentation Multi Conductor Stranded 19x29 Non Plenum Cable
- Belden 9721 Cable 16 AWG 8 Conductors Audio Control and Instrumentation Multi Conductor Stranded 19x29 Non Plenum Cable
- Belden 9621 Cable 16 AWG 9 Conductors Audio Control and Instrumentation Multi Conductor Stranded 19x29 Non Plenum Cable
- Belden 8622 Cable 16 AWG 12 Conductors Audio Control and Instrumentation Multi Conductor Stranded 19x29 Non Plenum Cable
- Belden 8623 Cable 16 AWG 15 Conductors Audio Control and Instrumentation Multi Conductor Stranded 19x29 Non Plenum Cable
- Belden 8624 Cable 16 AWG 19 Conductors Audio Control and Instrumentation Multi Conductor Stranded 19x29 Non Plenum Cable
- Belden 9622 Cable 16 AWG 25 Conductors Audio Control and Instrumentation Multi Conductor Stranded 19x29 Non Plenum Cable
Description:
• 16 AWG stranded (19x29) tinned copper conductors, conductors cabled, PVC insulation, cabled wire (no jacket).
Insulation:
• Material: PVC - Polyvinyl Chloride
• Wall Thickness (mm): 0.6858
• Dia. (mm): 2.8702
Outer Jacket:
• Material: Unjacketed
Mechanical Charactertistics (Overall):
• Operating Tempeature Range: -40°C To +80°C
• UL Temperature Rating: 80°C (UL AWM Style 1007)
• Bulk Cable Weight: 56.552 Kg/Km
• Max. Recommended Pulling Tension: 431.475 N
• Min. Bend Radius/Minor Axis: 63.500 mm
Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• AWM Specification: UL Style 1007 (300 V 80°C)
• EU Directive 2011/65/EU (ROHS II): Yes
• EU CE Mark: Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 04/01/2005
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes
Electrical Characteristics (Overall):
• Nom. Conductor DC Resistance @ 20°C (Ohm/km): 15.7488
• Max. Operating Voltage - UL: 300 V RMS (UL AWM Style 1007)
• Max. Recommended Current: 7.1 Amps/Conductor @ 25°C
Flame Test:
• UL Flame Test: VW-1
Plenum/Non-Plenum:
• Plenum (Y/N): No
technical specification: | |
awg | 16 |
# conductors | 3 |
stranding | 19x29 |
no. of conductors | 3 |
conductor material | tinned copper |
dia. (mm) | 1.4986 |
outer shield - material | unshielded |
overall cable- nominal dia. (mm) | 6.172 |
belden cable part number | 9498 |