Belden 9841 Cable 24 AWG 1 Pair Stage Lighting Low Capacitance Computer Non Plenum PVC Jacket Cable

Belden 9841 Cable 24 AWG 1 Pair Stage Lighting Low Capacitance Computer Non Plenum PVC Jacket Cable

Select gauge from drop-down menu for prices:

Belden 9841 Cable 24 AWG 1 Pair Stage Lighting Low Capacitance Computer Non Plenum PVC Jacket Cable

Precio habitual $2.49 Oferta /per Foot

Belden 9841 Cable 24 AWG 1 Pair Stage Lighting Low Capacitance Computer Non Plenum PVC Jacket Cable

Description:
• 24 AWG stranded (7x32) TC conductors, polyethylene insulation, twisted pairs, overall Beldfoil® (100% coverage) + TC braid shield (90% coverage), 24 AWG stranded TC drain wire, PVC jacket.

Insulation:
• Material: PE - Polyethylene
• Wall Thickness (in.): 0.023

Outer Shield Drain Wire AWG:
• AWG: 24
• Stranding: 7x32
• Material: Tinned Copper

Outer Jacket:
• Material: PVC - Polyvinyl Chloride
• Nom. Wall Thickness (in.): 0.035

Overall Cabling Lay Length & Direction:
• Length (in.): 2.500
• Direction: Left Hand
• Twists (twist/ft): 4.800

Usage (Overall):
• Applications: RS-485, DMX-512

Mechnical Characteristics (Overall):
• Operating Temperature Range: -30°C To +80°C
• Bulk Cable Weight: 36 lbs/1000 ft.
• Max. Recommended Pulling Tension: 72.300 lbs.
• Min. Bend Radius/Minor Axis: 2.500 in.

Applicable Specifications and Agency Compliance (Overall):
Applicable Standards & Environmental Programs:
• NEC/(UL) Specification: CM
• NEC Articles: 800
• CEC/C(UL) Specification: CM
• AWM Specification: UL Style 2919 (30 V 80°C)
• EU Directive 2011/65/EU (ROHS II): Yes
• EU CE Mark: Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 01/01/2004
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire & Cable): Yes
• MII Order #39 (China RoHS): Yes

Electrical Characteristics (Overall):
• Nom. Characteristic Impedance (Ohm): 120
• Nom. Capacitance Conductor to Conductor (pF/ft): 12.8
• Nom. Capacitance Cond. to Other Conductor & Shield (pF/ft): 23
• Nominal Velocity of Propagation VP (%): 66
• Nominal Delay (ns/ft): 1.6
• Nom. Conductor DCR @ 20°C (Ohm/1000 ft): 24
• Nom. Outer Shield DCR @ 20°C (Ohm/1000 ft): 3.4
• Max.Operating Voltage - UL: 300 V RMS (Type CM)
• Max.Operating Voltage - UL: 300 V RMS (AWM2919)
• Max. Recommended Current: 2.1 Amps per conductor @ 25°C ambient (10C temperature rise)

Flame Test:
• UL Flame Test: UL1685 UL Loading
• CSA Flame Test: FT1

Suitability:
• Suitability - Indoor: Yes

Plenum/Non-Plenum:
• Plenum (Y/N): No
• Plenum Number: 82841, 89841

Benefits And Features:
• Belden offers more than 25 variations for DMX / RS-485 applications
• Many of Belden's lighting cables are designed for industrial standards, and their rugged and resistant cable options are suitable for many indoor and outdoor lighting challenges

technical specification:
awg 24
# pair 1
stranding 7x32
no. of conductors 2
conductor material tinned copper
dia. (in.) -
outer shield - type tape
outer shield - material aluminum foil-polyester tape
overall cable - nominal dia. (in.) 0.232
belden cable part number 9841