Belden Cable 2 AWG 4 Conductors Marine Classic 300% Ground Foil/Braid Design Thermoset LSZH Jacket VFD Cable 29507X
Select gauge from drop-down menu for prices:
- Belden Cable Marine Classic 300% Ground Foil/Braid Design Thermoset LSZH Jacket VFD Cable
- Belden Cable 16 AWG 4 Conductors Marine Classic 300% Ground Foil/Braid Design Thermoset LSZH Jacket VFD Cable 29500X
- Belden Cable 14 AWG 4 Conductors Marine Classic 300% Ground Foil/Braid Design Thermoset LSZH Jacket VFD Cable 29501X
- Belden Cable 12 AWG 4 Conductors Marine Classic 300% Ground Foil/Braid Design Thermoset LSZH Jacket VFD Cable 29502X
- Belden Cable 10 AWG 4 Conductors Marine Classic 300% Ground Foil/Braid Design Thermoset LSZH Jacket VFD Cable 29503X
- Belden Cable 8 AWG 4 Conductors Marine Classic 300% Ground Foil/Braid Design Thermoset LSZH Jacket VFD Cable 29504X
- Belden Cable 6 AWG 4 Conductors Marine Classic 300% Ground Foil/Braid Design Thermoset LSZH Jacket VFD Cable 29505X
- Belden Cable 4 AWG 4 Conductors Marine Classic 300% Ground Foil/Braid Design Thermoset LSZH Jacket VFD Cable 29506X
Classic Foil/Braid Designs Features:
• High-strand conductors ease installation; enable better vibration resistance
• Full-sized insulated ground allows lower resistance path to ground
• Tinned copper conductors to prevent against corrosion
• Low capacitance and low impedance of the cables closely matches the drive and electrical values
• Round configuration for reliable sealing
• Optimum shielding design (300%/100% copper at ground potential)
• Heavy industrial-grade XLPE insulation
• Finely stranded tinned or bare copper conductors
Technical Data:
• Type: Premium 300% ground four conductor
• Shielding: Foil + Braid
• Grounding: Full Size Insulated
• Insulation: XLPE (RHHW-2 Thickness)
• Conductor: Stranded Tinned Copper
• Rating: 1000V UL Flexible Motor Supply
• 600V UL 1277 Type TC-ER
• CSA FT4
• IEEE 1202
• UL Oil Res 2 & IEC 60811-2-1 Hydrocarbon resistant
• UL 1685 Vertical Tray Flame Test
• XHHW-2, RHW-2 rated circuit conductors -14 AWG and larger
• 90° C Wet/Dry
• -40° C cold bend, IEC 60332-3-22 Cat A (flame test)
• Suitable for Class I, II & III, Division 2 hazardous locations
• IEC 60754-1,-2 (acid gas emissions)
• MSHA (pending approval)
• RoHS compliant
• CE approved
• Marine approvals: ABS, DNV, UL 1309, IEEE 45, IEEE1580 Type P
Benefits:
• Superior protection against electrical noise
• Increased stability in electrical performance
• Improved system uptime in harsh environments
technical specifications: | |
awg | 2 |
cond. stranding | 7 x 19 x 23 |
standard lengths(ft) | 1000 |
standard lengths(m) | 304.8 |
standard unit wt(lbs.) | 1789.0 |
standard unit wt(kg) | 811.5 |
nominal od(inch) | 1.31 |
nominal od(mm) | 33.27 |
maximum pull tension(lbs.) | 3088 |
maximum pull tension(n) | 13742 |
minimum bend radius(inch) | 10.8 |
minimum bend radius(mm) | 273.1 |
belden cable part number | 29507X |