HW355 Telephone Cable Filled, Direct Burial RUS / REA Specification PE-89 - 22 AWG - 100 Pairs
Select gauge from drop-down menu for prices:
- HW355 Telephone Cable Filled, Direct Burial RUS / REA Specification PE-89
- HW355 Telephone Cable Filled, Direct Burial RUS / REA Specification PE-89 - 24 AWG - 6 Pairs
- HW355 Telephone Cable Filled, Direct Burial RUS / REA Specification PE-89 - 24 AWG - 12 Pairs
- HW355 Telephone Cable Filled, Direct Burial RUS / REA Specification PE-89 - 24 AWG - 25 Pairs
- HW355 Telephone Cable Filled, Direct Burial RUS / REA Specification PE-89 - 24 AWG - 50 Pairs
- HW355 Telephone Cable Filled, Direct Burial RUS / REA Specification PE-89 - 24 AWG - 100 Pairs
- HW355 Telephone Cable Filled, Direct Burial RUS / REA Specification PE-89 - 24 AWG - 200 Pairs
- HW355 Telephone Cable Filled, Direct Burial RUS / REA Specification PE-89 - 24 AWG - 300 Pairs
- HW355 Telephone Cable Filled, Direct Burial RUS / REA Specification PE-89 - 22 AWG - 6 Pairs
- HW355 Telephone Cable Filled, Direct Burial RUS / REA Specification PE-89 - 22 AWG - 12 Pairs
- HW355 Telephone Cable Filled, Direct Burial RUS / REA Specification PE-89 - 22 AWG - 25 Pairs
- HW355 Telephone Cable Filled, Direct Burial RUS / REA Specification PE-89 - 22 AWG - 50 Pairs
- HW355 Telephone Cable Filled, Direct Burial RUS / REA Specification PE-89 - 19 AWG - 6 Pairs
- HW355 Telephone Cable Filled, Direct Burial RUS / REA Specification PE-89 - 19 AWG - 12 Pairs
- HW355 Telephone Cable Filled, Direct Burial RUS / REA Specification PE-89 - 19 AWG - 25 Pairs
- HW355 Telephone Cable Filled, Direct Burial RUS / REA Specification PE-89 - 19 AWG - 50 Pairs
Product Details
Technical Specifications: | |
Catalog Number | HW355 22100 |
Size AWG | 22 |
No. of Pairs | 100 |
Overall Diameter | 1.13 |
Net Weight Lbs/Mft | 701 |
Specifications:
- HW355
- Telephone Cable
- Filled, Direct Burial
- RUS / REA Specification PE-89
Application:
For use in wet environments where protection from moisture is required. Approved for direct burial, duct or aerial installations when supported by a messenger.
Conductors:
Solid soft bare annealed copper. Individual conductors are twisted into pairs with varying lay lengths to minimize crosstalk.
Insulation:
Dual layer of foamed polyolefin and solid polyolefin.
Filling Compound:
Cable core is filled with an extended thermoplastic rubber (ETPR) filling the interstices between the pairs and under the core tape.
Core Wrap:
Non-hygroscopic, dielectric tape with overlap.
Shield:
Corrugated, copolymer coated, 8-mil aluminum tape longitudinally applied with overlap. The shield interfaces are flooded with an adhesive compound to provide a moisture barrier and inhibit corrosion.
Jacket:
Black, sunlight-resistant, linear low-density polyethylene.
Color Code:
Color code chart 5.
Additional Standards:
ANSI/ICEA S-84-608-1994 • RUS 7 CFR 1755.890 (formerly REA PE-89)