600 Volt UL Type MC, XLP XHHW-2 Insulation - HW306 01403

600 Volt UL Type MC, XLP XHHW-2 Insulation - HW306 01403

Select gauge from drop-down menu for prices:

600 Volt UL Type MC, XLP XHHW-2 Insulation - HW306 01403
Technical Specifications:
Catalog Number HW306 01403
Size AWG 14
No. of Conductors 3
No. of Strands 7
Insulation Thickness Mils 30
Jacket Thickness Mils 50
Class 1 Div. 2 Connector No. 424CU02
Rain Tight Connector No. 416MC02
Armor Diameter Inch 0.44
Overall Diameter Inch 0.55
Net Weight Lbs/Mft 155

Specifications:

  • Impervious Continuously Welded Armor - Control Cable
  • 600 Volt UL Type MC, CT Use, 90°C
  • XLP XHHW-2 Insulation
  • Aluminum Armor
  • Copper Conductors

Application:
For use in harsh environments where maximum conductor protection is required. Impervious armor prevents the entrance of water, gas and corrosive elements into the electrical core. Used for power, control and lighting circuits in a broad range of commercial and industrial pulp and paper, mining, and petroleum applications. Approved for use in wet or dry locations at 90°C, for installation indoors or outdoors, aerially, in conduits, ducts, cable trays or direct burial in circuits not exceeding 600 volts. May be used in NEC Class I and II, Division 2 and Class III, Division 1 and 2 hazardous locations. UL approved for use at 90°C for continuous operation, 130°C for emergency overload conditions, and 250°C for short circuit conditions. Impervious continuously welded corrugated armor cable is recommended as an economical alternative to wire in conduit systems.

Conductors:
Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 (compressed) or ASTM B-496 (compact).

Insulation:
Cross-linked polyethylene (XLP) per ICEA S-95-658 and UL Standard 44 for Type XHHW-2 conductors.

Armor:
Impervious continuously welded and corrugated aluminum.

Jacket:
Black sunlight-resistant PVC

Flame Tests:

  • UL 1581 70,000 BTU/hr flame test
  • ICEA 70,000 BTU/hr and 210,000 BTU/hr flame test
  • IEEE 383 70,000 BTU/hr flame test

Color Code:
ICEA Method 1, Table E-2

Additional Standards:

  • UL listed, NEC Type MC, UL Standard 1569
  • UL listed Type CWCMC to IEEE 45/IEEE 1580 (46 CFR Part 111.60-23) Marine Shipboard Cable.
  • Meets requirements of CSA-C22.2 No. 0.3, -40°C cold impact test

Connectors:

  • Explosion Proof, Class 1 Division 2: 424CU series – aluminum exterior components, nickel-plated brass interior components
  • Rain Tight: 416MC series – all nickel-plated brass

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.

Ask a Question