600 Volt UL Type MC-HL, 90 XLP XHHW-2 Insulation - HW308 08003
Select gauge from drop-down menu for prices:
Technical Specifications: | |
Catalog Number | HW308 08003 |
Power Size AWG | 8 |
P-No. of Conductors | 3 |
P-Insulation Mils | 45 |
Jacket Thickness Mils | 50 |
Ground Wire Size AWG | 10 |
Control Size AWG | 12 |
C-No. of Conductors | 4 |
C-Insulation Thickness Mils | 30 |
Class 1 Div. 2 Connector No. | 424MA04 |
Rain Tight Connector No. | 416MC05 |
Armor Diameter Inch | 0.92 |
Overall Diameter Inch | 1.05 |
Net Weight Lbs/Mft | 510 |
Specifications:
- Impervious Continuously Welded Armor - Power and Control Composite Cable
- 600 Volt UL Type MC-HL, CT Use, 90°C
- XLP XHHW-2 Insulation
- Aluminum Armor
- Copper Conductors
Application:
For use in harsh environments where maximum conductor protection is required. Impervious armor prevents the entrance of water, gas and corrosive elements into the electrical core. Used for power, control and lighting circuits in a broad range of commercial and industrial pulp and paper, mining, and petroleum applications. Approved for use in wet or dry locations at 90°C, for installation indoors or outdoors, aerially, in conduits, ducts, cable trays or direct burial in circuits not exceeding 600 volts. UL listed, Type MC-HL per UL Standard 2225 for use in Class I, Division I hazardous locations. UL approved for use at 90°C for continuous operation, 130°C for emergency overload conditions, and 250°C for short circuit conditions. Impervious continuously welded corrugated armor cable is recommended as an economical alternative to wire in conduit systems.
Conductors:
Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 (compressed) or ASTM B-496 (compact).
Insulation:
Cross-linked polyethylene (XLP) per ICEA S-95-658 and UL Standard 44 for Type XHHW-2 conductors.
Grounding Conductor: Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 sized in accordance with NEC requirements.
Armor:
Impervious continuously welded and corrugated aluminum.
Jacket:
Black flame-retardant and sunlight-resistant PVC.
Flame Tests:
- UL 1581 70,000 BTU/hr flame test
- ICEA 70,000 BTU/hr and 210,000 BTU/hr flame test
- IEEE 383 70,000 BTU/hr flame test
Color Code:
- Control Conductors: red, blue, orange and yellow
- Power Conductors: ICEA Method 4
Additional Standards:
- UL listed Type CWCMC to IEEE 45/IEEE 1580 (46 CFR Part 111.60-23) Marine Shipboard Cable.
- Meets requirements of CSA-C22.2 No. 0.3, -40°C cold impact test
Connectors:
- Explosion Proof, Class 1 Division 1: 424MA series - all nickel-plated brass
- Rain Tight: 416MC series - all nickel-plated brass