2.4KV UL Type MV 105, MC-HL, CT, 105, EPR Insulation - HW309 25003
Select gauge from drop-down menu for prices:
- 2.4KV UL Type MV 105, MC-HL, CT, 105, EPR Insulation
- 2.4KV UL Type MV 105, MC-HL, CT, 105, EPR Insulation - HW309 00603
- 2.4KV UL Type MV 105, MC-HL, CT, 105, EPR Insulation - HW309 00403
- 2.4KV UL Type MV 105, MC-HL, CT, 105, EPR Insulation - HW309 00203
- 2.4KV UL Type MV 105, MC-HL, CT, 105, EPR Insulation - HW309 00103
- 2.4KV UL Type MV 105, MC-HL, CT, 105, EPR Insulation - HW309 10103
- 2.4KV UL Type MV 105, MC-HL, CT, 105, EPR Insulation - HW309 20103
- 2.4KV UL Type MV 105, MC-HL, CT, 105, EPR Insulation - HW309 40103
- 2.4KV UL Type MV 105, MC-HL, CT, 105, EPR Insulation - HW309 35003
- 2.4KV UL Type MV 105, MC-HL, CT, 105, EPR Insulation - HW309 50003
Technical Specifications: | |
Catalog Number | HW309 25003 |
Size AWG/kcmil | 250 |
No. of Conductors | 3 |
No. of Strands | 19 |
Insulation Thickness Mils | 90 |
Jacket Thickness Mils | 60 |
Ground Wire Size No.- AWG | 3-7 |
Class 1 Div. 2 Connector No. | 416MA07V |
Rain Tight Connector No. | 416MC08 |
Armor Diameter Inch | 2.02 |
Overall Diameter Inch | 2.15 |
Net Weight Lbs/Mft | 3475 |
Specifications:
- Impervious Continuously Welded Armor - Power Cable
- 2.4KV UL Type MV 105, MC-HL, CT Use, 105°C
- Non-Shielded, EPR Insulation
- 133% Insulation Level
- Aluminum Armor
- Copper Conductors
Application:
For use in harsh environments where maximum conductor protection is required. Used for primary power and feeder circuits in a broad range of commercial and industrial power distribution systems. Approved for use in wet or dry locations at 105°C, for installation indoors or outdoors, aerially, in conduits, ducts, cable trays or direct burial in circuits not exceeding 2400 volts. May be used in NEC Class I and II, Division 2 and Class III, Division 1 and 2 hazardous locations. National Electric Code approved for use at 105°C for continuous operation, 140°C for emergency overload conditions, and 250°C for short circuit conditions. Impervious continuously welded and corrugated aluminum armor cable is recommended as an economical alternative to wire in conduit systems.
Conductors:
Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 (compressed) or ASTM B-496 (compact), with a semi-conducting conductor shield.
Insulation:
Ethylene propylene rubber (EPR) per ICEA S-96-659.
Grounding Conductor: Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 sized in accordance with UL 1072.
Armor:
Impervious continuously welded and corrugated aluminum.
Jacket:
Yellow flame-retardant and sunlight-resistant PVC.
Flame Tests:
ICEA 70,000 BTU/hr and 210,000 BTU/hr flame test
Color Code:
ICEA Method 4
Additional Standards:
- NEMA WC 71
- UL 1309 listed as Marine Shipboard Cable
Connectors:
- Explosion Proof, Class I Division 1: 424MA series - exterior components - aluminum, interior components - nickel-plated brass
- Rain Tight: 416MC series - all nickel-plated brass
- See 424MA series in Section J.