Corning 036T88-61131-29 36 Fiber 50 µm Multimode MIC Unitized Tight-Buffered Plenum Cable
Select gauge from drop-down menu for prices:
Corning 036T88-61131-29 36 Fiber 50 µm Multimode MIC Unitized Tight-Buffered Plenum Cable
- Corning 36 to 144 Fiber Single and Multimode MIC Unitized Tight-Buffered Plenum Cable
- Corning 048T88-61131-29 48 Fiber 50 µm Multimode MIC Unitized Tight-Buffered Plenum Cable
- Corning 060T88-T3131-29 60 Fiber 50 µm Multimode MIC Unitized Tight-Buffered Plenum Cable
- Corning 072T88-T3131-29 72 Fiber 50 µm Multimode MIC Unitized Tight-Buffered Plenum Cable
- Corning 096T88-Y3131-29 96 Fiber 50 µm Multimode MIC Unitized Tight-Buffered Plenum Cable
- Corning 144T88-Y3131-29 144 Fiber 50 µm Multimode MIC Unitized Tight-Buffered Plenum Cable
- Corning 036K88-61130-29 36 Fiber 62.5 µm Multimode MIC Unitized Tight-Buffered Plenum Cable
- Corning 048K88-61130-29 48 Fiber 62.5 µm Multimode MIC Unitized Tight-Buffered Plenum Cable
- Corning 060K88-T3130-29 60 Fiber 62.5 µm Multimode MIC Unitized Tight-Buffered Plenum Cable
- Corning 072K88-T3130-29 72 Fiber 62.5 µm Multimode MIC Unitized Tight-Buffered Plenum Cable
- Corning 096K88-Y3130-29 96 Fiber 62.5 µm Multimode MIC Unitized Tight-Buffered Plenum Cable
- Corning 144K88-Y3130-29 144 Fiber 62.5 µm Multimode MIC Unitized Tight-Buffered Plenum Cable
- Corning 036E88-61131-29 36 Fiber Singlemode MIC Unitized Tight-Buffered Plenum Cable
- Corning 048E88-61131-29 48 Fiber Singlemode MIC Unitized Tight-Buffered Plenum Cable
- Corning 060E88-T3131-29 60 Fiber Singlemode MIC Unitized Tight-Buffered Plenum Cable
- Corning 072E88-T3131-29 72 Fiber Singlemode MIC Unitized Tight-Buffered Plenum Cable
- Corning 096E88-Y3131-29 96 Fiber Singlemode MIC Unitized Tight-Buffered Plenum Cable
- Corning 144E88-Y3131-29 144 Fiber Singlemode MIC Unitized Tight-Buffered Plenum Cable
MIC® Unitized Tight-Buffered Cable, Plenum, 36 F, 50 µm multimode (OM2)
Cable Design:
• Central Element: Jacketed GRP
• Fiber Count: 36
• Number of Active Tubes: 6
• Fibers per Subunit: 6
• Subunit Color: Orange
• Subunit Diameter: 4.40 mm ( 0.17 in)
• Tight Buffer Color Subunit: Blue, Orange, Green, Brown, Slate, White
• Tensile Strength Elements and/or Armoring - Layer 1: Dielectric strength members
• Number of Ripcords: 7
• Outer Jacket Material: Flame-retardant
• Outer Jacket Color: Orange
technical specification | |
fiber count | 36 |
fiber category | 50 µm MM (OM2) |
no. of active tubes | 6 |
fibers per subunit | 6 |
subunit diameter | 4.40 mm ( 0.17 in) |
nominal outer diameter | 14.8 mm (0.58 in) |
weight (kg/km) | 207.3 |
weight (lb/1000 ft) | 147.0 |