HW292 HL Listed CIR® Instrumentation Cable Individually Shielded Triads + Ground 0.6/1kV 90°C Gexol® Insulation - 16 AWG -12 Triads

HW292 HL Listed CIR® Instrumentation Cable Individually Shielded Triads + Ground 0.6/1kV 90°C Gexol® Insulation - 16 AWG -12 Triads

HW292 HL Listed CIR® Instrumentation Cable Individually Shielded Triads + Ground 0.6/1kV 90°C Gexol® Insulation - 16 AWG -12 Triads
Technical Specifications:
Catalog Number/HWC Part # HW292 01612
Size AWG 16
Size (mm2)
1.3
Triads 12
Nominal Diameter (inches) 1.395
Weight (lbs./1000 ft.) 1235
DC Resistance at 20°C (Ohms/1000 ft.) 4.52
Mutual Capacitance (nF/1000 ft.) 32
Inductance (mH/1000 ft.) 0.2
HL Listed --

Specifications:

  • HW292
  • HL Listed CIR® Instrumentation Cable*
  • Individually Shielded Triads + Ground
  • 0.6/1kV 90°C Gexol® Insulation

Application:
Designed and constructed to be a flexible alternative to Type MC cable where crush and impact protection in arctic conditions is required.

Conductors:
Soft annealed flexible stranded tinned copper per IEEE 1580 Table 11.

Insulation:
Gexol cross-linked flame retardant polyolefin, meets requirements for Type P of IEEE 1580 and Type X110 of UL 1309/CSA 245. 600V/IEC 1000V

Shielding:
Each pair/triad is twisted with a bare tinned drain wire. Each pair/triad is shielded with polyester-backed aluminum foil tape to afford 100% coverage. Pair to pair or triad to triad, isolation – plus overall shielding – is provided.

Grounding Conductor:
Soft annealed, flexible stranded, uninsulated, tinned copper sized in accordance with UL 1277.

Jacket:
A black, flame retardant, oil, abrasion, chemical and sunlight resistant thermoset compound meeting UL 1309/CSA 245 and IEEE 1580.

Ratings & Approvals :

  • 90°C temperature rating
  • UL Listed as Marine Shipboard Cable (E111461)
  • UL Listed as Type TC-ER
  • UL Listed as Type TC-ER-HL*
  • American Bureau of Shipping (ABS) (99-BT5905-X)
  • Flame Retardant – IEEE 1202
  • Suitable for use in Class I, Div 2 & Zone 2 environments
  • Suitable for use in Class I, Div 1 & Zone 1 environments*
  • *Cables up to 1” in OD

Features:

  • Complies with the requirements for TC-ER-HL* per UL 2225
  • Gas & vapor tight – impervious to water and air
  • Smaller bend radius (up to 40% smaller) than Type MC
  • Reduced tray fill (up to 35% less) compared to Type MC
  • Considerably more flexible than Type MC
  • Brittle point as per ASTM D 746-07 exceeds -65°C for Jacket and -75°C for Insulation
  • Exceeds CSA cold bend / cold impact (-40°C / -35°C)

Instrumentation Cable Color Legend:

Pairs Black, White
Triads Black, White, Red


QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.

Ask a Question