Deca Cables 18 AWG 24 Triads 300V CSA Instrumentation Tray Cable 96-1898
Select gauge from drop-down menu for prices:
Deca Cables 18 AWG 24 Triads 300V CSA Instrumentation Tray Cable 96-1898
- Deca Cables Multi Pairs/Triads 300V CSA Tray Instrumentation Cable
- Deca Cables 20 AWG 1 Pair 300V CSA Instrumentation Tray Cable
- Deca Cables 20 AWG 2 Pairs 300V CSA Instrumentation Tray Cable
- Deca Cables 20 AWG 4 Pairs 300V CSA Instrumentation Tray Cable 95-2034
- Deca Cables 20 AWG 6 Pairs 300V CSA Instrumentation Tray Cable
- Deca Cables 20 AWG 8 Pairs 300V CSA Instrumentation Tray Cable 95-2038
- Deca Cables 20 AWG 12 Pairs 300V CSA Instrumentation Tray Cable 95-2042
- Deca Cables 20 AWG 16 Pairs 300V CSA Instrumentation Tray Cable
- Deca Cables 20 AWG 24 Pairs 300V CSA Instrumentation Tray Cable
- Deca Cables 20 AWG 36 Pairs 300V CSA Instrumentation Tray Cable
- Deca Cables 20 AWG 1 Triad 300V CSA Instrumentation Tray Cable
- Deca Cables 20 AWG 2 Triads 300V CSA Instrumentation Tray Cable
- Deca Cables 20 AWG 4 Triads 300V CSA Instrumentation Tray Cable
- Deca Cables 20 AWG 6 Triads 300V CSA Instrumentation Tray Cable
- Deca Cables 20 AWG 8 Triads 300V CSA Instrumentation Tray Cable 96-2088
- Deca Cables 20 AWG 12 Triads 300V CSA Instrumentation Tray Cable
- Deca Cables 20 AWG 16 Triads 300V CSA Instrumentation Tray Cable
- Deca Cables 20 AWG 24 Triads 300V CSA Instrumentation Tray Cable
- Deca Cables 18 AWG 1 Pair 300V CSA Instrumentation Tray Cable 95-1831
- Deca Cables 18 AWG 2 Pairs 300V CSA Instrumentation Tray Cable 95-1882
- Deca Cables 18 AWG 4 Pairs 300V CSA Instrumentation Tray Cable 95-1884
- Deca Cables 18 AWG 6 Pairs 300V CSA Instrumentation Tray Cable 95-1886
- Deca Cables 18 AWG 8 Pairs 300V CSA Instrumentation Tray Cable 95-1888
- Deca Cables 18 AWG 12 Pairs 300V CSA Instrumentation Tray Cable 95-1892
- Deca Cables 18 AWG 16 Pairs 300V CSA Instrumentation Tray Cable 95-1896
- Deca Cables 18 AWG 24 Pairs 300V CSA Instrumentation Tray Cable 95-1896
- Deca Cables 18 AWG 36 Pairs 300V CSA Instrumentation Tray Cable 95-1899
- Deca Cables 18 AWG 1 Triad 300V CSA Instrumentation Tray Cable 96-1881
- Deca Cables 18 AWG 2 Triads 300V CSA Instrumentation Tray Cable 96-1882
- Deca Cables 18 AWG 4 Triads 300V CSA Instrumentation Tray Cable 96-1884
- Deca Cables 18 AWG 6 Triads 300V CSA Instrumentation Tray Cable 96-1886
- Deca Cables 18 AWG 8 Triads 300V CSA Instrumentation Tray Cable 96-1888
- Deca Cables 18 AWG 12 Triads 300V CSA Instrumentation Tray Cable 96-1892
- Deca Cables 18 AWG 16 Triads 300V CSA Instrumentation Tray Cable 96-1896
- Deca Cables 16 AWG 1 Pair 300V CSA Instrumentation Tray Cable 95-1631
- Deca Cables 16 AWG 2 Pairs 300V CSA Instrumentation Tray Cable 95-1632
- Deca Cables 16 AWG 4 Pairs 300V CSA Instrumentation Tray Cable 95-1634
- Deca Cables 16 AWG 6 Pairs 300V CSA Instrumentation Tray Cable 95-1636
- Deca Cables 16 AWG 8 Pairs 300V CSA Instrumentation Tray Cable 95-1638
- Deca Cables 16 AWG 12 Pairs 300V CSA Instrumentation Tray Cable 95-1642
- Deca Cables 16 AWG 16 Pairs 300V CSA Instrumentation Tray Cable 95-1646
- Deca Cables 16 AWG 24 Pairs 300V CSA Instrumentation Tray Cable 95-1649
- Deca Cables 16 AWG 36 Pairs 300V CSA Instrumentation Tray Cable 95-1650
- Deca Cables 16 AWG 1 Triad 300V CSA Instrumentation Tray Cable 96-1631
- Deca Cables 16 AWG 2 Triads 300V CSA Instrumentation Tray Cable 96-1632
- Deca Cables 16 AWG 4 Triads 300V CSA Instrumentation Tray Cable 96-1634
- Deca Cables 16 AWG 6 Triads 300V CSA Instrumentation Tray Cable 96-1636
- Deca Cables 16 AWG 8 Triads 300V CSA Instrumentation Tray Cable 96-1638
- Deca Cables 16 AWG 12 Triads 300V CSA Instrumentation Tray Cable 96-1642
- Deca Cables 16 AWG 16 Triads 300V CSA Instrumentation Tray Cable 96-1646
- Deca Cables 16 AWG 24 Triads 300V CSA Instrumentation Tray Cable 96-1647
Conductor: 7 strand tinned copper - Class B concentric
Drain Wire: 22 AWG 7 strand tinned copper - Class B concentric
Insulation: Cross-linked polyethylene (XLPE)
Individual Shield: Aluminum mylar tape shield with drain wire - Multi-pair/triad only
Overall Shield: Aluminum mylar tape shield with drain wire
Outer Jacket: Low-temperature (-40°C), flame and sunlight resistant Polyvinyl Chloride (PVC), Direct Burial, Black
Voltage: 300V
Options: Various colours for outer jackets PVC insulation available upon request
Specifications:
• CSA C22.2 No. 239 & CSA C22.2 No. 174
• CSA C22.2 NO. 38, CSA FT4 (Vertical Tray Flame Test)
technical specification: | |
conductor size awg | 18 |
no. of pairs/triads | 24 |
insulation thickness (inches) | 0.025 |
insulation thickness (mm) | 0.64 |
nominal diameter outer jacket (inches) | 1.327 |
nominal diameter outer jacket (mm) | 33.7 |
cable weight (lbs/mft) | 847 |
cable weight (kg/km) | 1260 |
minimum bend radius (inches) | 16 |
minimum bend radius (mm) | 404 |
maximum pulling tension (lbs) | 1,019 |
maximum pulling tension (kgs) | 462 |
Deca Cables Part Number | 96-1898 |