General Cable EmPowr® 2 AWG 5 kV Copper Wire PVC Jacket Fill Shielded Power Cable Al Conductor EPR Insulation 115 mils

General Cable EmPowr® 2 AWG 5 kV Copper Wire PVC Jacket Fill Shielded Power Cable Al Conductor EPR Insulation 115 mils

EmPowr 2 AWG 5 kV Copper Wire PVC Jacket Fill Shielded Power Cable Al Conductor EPR Insulation 115 mils

Complete Cable: Cross-linked semi-conducting conductor shield, insulation and semi-conducting insulation shield are extruded over a solid or stranded aluminum conductor and cured in a single operation. Uncoated copper wires (helically applied), separator tape and overlaying black PVC jacket are applied over the cable core. These products meet the latest requirements of ANSI/ICEA S-97- 682 and AEIC CS8 as applicable for Ethylene Propylene Rubber (EPR) insulated shielded power cable. 

Conductor: Solid or Class B compressed concentric lay stranded 1350 aluminum. 

Conductor Shield: Extruded semi-conducting thermosetting polymeric stress control layer. 

Insulation: Extruded Ethylene Propylene Rubber (EPR) Class II and III. 

Insulation Shield: Extruded semi-conducting thermosetting layer, clean and free stripping from insulation. 

Copper Wire Shield: Helically applied annealed solid bare copper wires with a lapped non-metallic tape serving as a binder/separator. 

Jacket: Black, non-conducting, sunlight-resistant Polyvinyl Chloride (PVC). 

Features and Benefits: 
• Triple-extruded for clean interfaces 
• Class 10,000 environment utilized for cable core material handling 
• Flexibility for easy handling 
• Excellent moisture resistance 
• Deformation-resistant 
• High dielectric strength 
• Low dielectric loss 
• Excellent resistance to water treeing 
• Clean-stripping insulation shield without the use of a release agent 
• Sunlight-resistant 

Temperature Rating: 
• Normal - 105°C 
• Emergency* - 140°C 
• Short Circuit - 250°C

Applications: EmPowr® Fill cables are intended for use in dry or wet locations for distribution of three-phase medium-voltage power. These cables may be installed in ducts or direct buried. 

Options: 
• Copper conductors 
• EmPowr® Fill LF Lead-Free EAM 
• STRANDFILL® blocked conductor. Tested in accordance with ICEA T-31-610 
• Dry nitrogen cure 
• True Triple Extrusion 
• 3 X 1/C triplex or parallel 
• Type MV-105 UL 1072 
• UL Listedb

technical specifications:
compressed conductor(al awg or kcmil) 2
compressed conductor(no.of wires) 7
copper neutral(no.of wires) 9
copper neutral(wire size awg)
24
diameter (1) inches (min. insulation ) 0.525
diameter (1) inches (max. insulation) 0.605
diameter (1) inches (pvc jacket) 0.787
nominal jacket thkn. inches (1) 0.065
approx. weight (1) lb/1000 ft(al cond.) 62
approx. weight (1) lb/1000 ft(cu shield) 12
approx. weight (1) lb/1000 ft(total)
284
ampacity (2)(directburied) 165
ampacity (2)(in duct) 125