Helukabel 10 AWG 5 Cores JZ-602-CY Screened Two Approval Control Cable Oil Resistant, EMC-preferred 90C 600V Cable 82952

Helukabel 10 AWG 5 Cores JZ-602-CY Screened Two Approval Control Cable Oil Resistant, EMC-preferred 90C 600V Cable 82952

Select gauge from drop-down menu for prices:

Helukabel 10 AWG 5 Cores JZ-602-CY Screened Two Approval Control Cable Oil Resistant, EMC-preferred 90C 600V Cable 82952
Helukabel 10 AWG 5 Cores JZ-602-CY Screened Two Approval Control Cable Oil Resistant, EMC-preferred 90C 600V Cable 82952

Technical Data:
• Control cable of special-PVC acc. to UL CSA AWM I/II A/B Style 2587 (sheath insulation) and CSA

Temperature Range
• flexing -5°C to +90°C
• fixed installation -40°C to +90°C

Nominal Voltage
• UL/CSA 600 V

Test Voltage
• 3000 V

Breakdown Voltage
• min. 6000 V

Insulation Resistance
• min. 20 MOhm x km

Minimum Bending Radius
• flexing 10x cable Ø
• fixed installation 5x cable Ø

Radiation Resistance
• up to 80x106 cJ/kg (up to 80 Mrad)

Coupling Resistance
• max. 250 Ohm/km

Cable Structure:
• Bare copper, fine wire stranded to DIN VDE 0295 cl.5, BS 6360 cl.5 and IEC 60228 cl.5
• Core insulation of PVC improved oil resistance test compound type TI3 to DIN VDE 0207-363-3 / DIN EN 50363-3 and class 43 acc. to UL Std.1581
• Core identification to DIN VDE 0293 black cores with continuous white numbering
• GN-YE conductor, 3 cores and above in the outer layer
• Cores stranded in layers with optimal lay length
• PVC-insulated inner sheath YM5 to DIN VDE 0207 part 5
• Braided screen of tinned Cu wires approx. 85% coverage
• Outer sheath of special PVC compound type YM5 to DIN VDE 0207 part 5 and class 43 acc. to UL Std.1581
• Sheath colour: grey (RAL 7001)
• With meter marking

Properties:
• Resistant to mineral oils, synthetic oils and coolant
• The outer sheath is approved with an improved oil resistance test
• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers.

Note:
• G = with GN-YE conductor x = without GN-YE conductor (OZ)
• Clean room qualification tested with analog type. Please note "cleanroom qualified" when ordering.
• AWG sizes are approximate equivalent (RAL 7001) values. The actual cross section is in mm²..
• Unscreened analogue type: JZ-602

Application:
• UL and CSA approved flexible control cables up to 600 V, for all machinery in tooling and plant construction, suitable for installation in dry, moist or wet environments for medium mechanical loads. Designed for the export-orientated machinery manufacturer, specifically for USA and Canada. The thick braiding screen ensures compliance with electromagnetic requirements.

technical specification:
awg 10
no.cores x cross-sec.mm² 5 G 6
outer ø app. mm 17,0
cop.weight kg/km 439,0
weight app.kg/km 732,0
helukabel part number 82952

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.

Ask a Question