Helukabel 12 AWG 4 Cores FROR CEI 20-22 II Bare Copper Conductor Cable 60274
Select gauge from drop-down menu for prices:
- Helukabel FROR CEI 20-22 II Bare Copper Conductor Cable
- Helukabel 17 AWG 3 Cores FROR CEI 20-22 II Bare Copper Conductor Cable 60250
- Helukabel 17 AWG 4 Cores FROR CEI 20-22 II Bare Copper Conductor Cable 60251
- Helukabel 17 AWG 5 Cores FROR CEI 20-22 II Bare Copper Conductor Cable 60252
- Helukabel 17 AWG 7 Cores FROR CEI 20-22 II Bare Copper Conductor Cable 60253
- Helukabel 17 AWG 12 Cores FROR CEI 20-22 II Bare Copper Conductor Cable 60254
- Helukabel 17 AWG 18 Cores FROR CEI 20-22 II Bare Copper Conductor Cable 60255
- Helukabel 17 AWG 25 Cores FROR CEI 20-22 II Bare Copper Conductor Cable 60256
- Helukabel 17 AWG 27 Cores FROR CEI 20-22 II Bare Copper Conductor Cable 60284
- Helukabel 17 AWG 33 Cores FROR CEI 20-22 II Bare Copper Conductor Cable 60285
- Helukabel 17 AWG 34 Cores FROR CEI 20-22 II Bare Copper Conductor Cable 60257
- Helukabel 17 AWG 42 Cores FROR CEI 20-22 II Bare Copper Conductor Cable 60258
- Helukabel 17 AWG 50 Cores FROR CEI 20-22 II Bare Copper Conductor Cable 60259
- Helukabel 16 AWG 3 Cores FROR CEI 20-22 II Bare Copper Conductor Cable 60260
- Helukabel 16 AWG 4 Cores FROR CEI 20-22 II Bare Copper Conductor Cable 60261
- Helukabel 16 AWG 5 Cores FROR CEI 20-22 II Bare Copper Conductor Cable 60262
- Helukabel 16 AWG 7 Cores FROR CEI 20-22 II Bare Copper Conductor Cable 60263
- Helukabel 16 AWG 12 Cores FROR CEI 20-22 II Bare Copper Conductor Cable 60264
- Helukabel 16 AWG 18 Cores FROR CEI 20-22 II Bare Copper Conductor Cable 60265
- Helukabel 16 AWG 25 Cores FROR CEI 20-22 II Bare Copper Conductor Cable 60266
- Helukabel 16 AWG 34 Cores FROR CEI 20-22 II Bare Copper Conductor Cable 60267
- Helukabel 16 AWG 37 Cores FROR CEI 20-22 II Bare Copper Conductor Cable 60286
- Helukabel 16 AWG 42 Cores FROR CEI 20-22 II Bare Copper Conductor Cable 60268
- Helukabel 16 AWG 50 Cores FROR CEI 20-22 II Bare Copper Conductor Cable 60269
- Helukabel 14 AWG 3 Cores FROR CEI 20-22 II Bare Copper Conductor Cable 60287
- Helukabel 14 AWG 4 Cores FROR CEI 20-22 II Bare Copper Conductor Cable 60270
- Helukabel 14 AWG 5 Cores FROR CEI 20-22 II Bare Copper Conductor Cable 60271
- Helukabel 14 AWG 7 Cores FROR CEI 20-22 II Bare Copper Conductor Cable 60272
- Helukabel 14 AWG 12 Cores FROR CEI 20-22 II Bare Copper Conductor Cable 60273
- Helukabel 12 AWG 7 Cores FROR CEI 20-22 II Bare Copper Conductor Cable 60275
- Helukabel 10 AWG 4 Cores FROR CEI 20-22 II Bare Copper Conductor Cable 60276
- Helukabel 8 AWG 4 Cores FROR CEI 20-22 II Bare Copper Conductor Cable 60277
- Helukabel 6 AWG 4 Cores FROR CEI 20-22 II Bare Copper Conductor Cable 60278
- Helukabel 4 AWG 4 Cores FROR CEI 20-22 II Bare Copper Conductor Cable 60279
- Helukabel 2 AWG 4 Cores FROR CEI 20-22 II Bare Copper Conductor Cable 60280
- Helukabel 1 AWG 4 Cores FROR CEI 20-22 II Bare Copper Conductor Cable 60281
- Helukabel 2/0 AWG 4 Cores FROR CEI 20-22 II Bare Copper Conductor Cable 60282
- Helukabel 3/0 AWG 4 Cores FROR CEI 20-22 II Bare Copper Conductor Cable 60283
Product Details
Technical data:
• Special PVC-sheath flexible cord as per Italian standard CEI 20-22
Temperature range
• flexing -5°C to +70°C
• fixed installation -35°C to +70°C
Nominal voltage
• up to 5-cores U0/U 450/750 V
• from 7-cores U0/U 300/500 V
Test voltage
• 2000 V
Insulation resistance
• min. 20 MOhm x km
Radiation resistance
• up to 80x106 cJ/kg (80 Mrad)
Minimum bending radius
• 10x cable Ø
Cable structure:
• Bare copper conductor, fine wire stranded to CEI 20-29 cl.5
• Special PVC compound TI2
• Core identification up to 4 cores to Helukabel®-JB colour code, from 5 cores black with continuous white number printing.
• GN-YE conductor
• Cores stranded in layers with optimal lay length
• Outer sheath of special PVC
• Sheath colour grey, similar to RAL 7035, with printing CEI 20-22 II
Properties:
• Oil- and petrol resistant as per CEI 20-22 II
• Conditionally resistant to Oil,Solvents, acids, lyes. The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers.
Application:
• Well known companies (FIAT, COMAU, etc.) use this cable for measurement and control purposes on machine tools and conveyors, as well as on production lines in equipment production and for special mechanical engineering. These cables are used for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in dry, moist and wet rooms but not suitable for open air. Due to special conductor insulation- and sheath compound, this cable is flame resistant in case of fire and self-extinguishing. The good oil- and petrol resistance allows the usage of this cable also in problem areas.
technical specification: | |
awg-no. | 12 |
No.cores x cross-sec. mm² | 4 G 4 |
outer ø app. mm | 14,0 |
cop. weight kg/km
|
154,0 |
weight app. kg/km | 300,0 |
Helukabel Part Number | 60274 |