Helukabel 18 AWG 16 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62911

Helukabel 18 AWG 16 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62911

Select gauge from drop-down menu for prices:

Helukabel 18 AWG 16 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62911
Helukabel 18 AWG 16 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62911

Technical data:
• PVC power cable acc. to UL Std.1277 and UL Std.2277

Temperature range:
• UL/CSA TC -40°C to +90°C
• UL/AWM -40°C to +90°C

Nominal voltage:
• TC 600 V
• AWM 1000 V
• WTTC 1000 V

Test voltage:
• 3000 V

Minimum bending|radius:
• 5x cable Ø

Insulation resistance:
• min. 20 MOhm x km

Radiation resistance:
• up to 80x106 cJ/kg (up to 80 Mrad)

Cable structure:
• Bare copper conductor, fine wire with AWG dimensions
• Core insulation of special PVC with transparent nylon skin
• Core identification to DIN VDE 0293 black cores with continuous white numbering
• GN-YE conductor, 3 cores and above in the outer layer
• Cores stranded in layers with optimal lay length
• Separator
• Outer sheath of special PVC
• Sheath colour: black (RAL 9005)
• With length marking in feet

Properties:
• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers
• UV resistant

Tests:
• Self-extinguishing and flame retardant acc. to CSA FT4

UL:
• TC-ER, PLTC-ER (AWG 18 - AWG 12), ITC-ER (AWG 18 - AWG 12), UL Type WTTC, UL Type MTW, NFPA 79, Oil Res I (Oil Res II also available), 90° C dry / 75° C wet, Class 1 Div. 2 per NEC Art. 336, 392, 501

CSA:
• c(UL) CIC-TC FT4, CSA AWM I/II A/B FT4

Note:
Advantages:
• TC-ER, Tray Cable Exposed Run
• Simple installation
• Outstanding flexibility

Application:
• NFPA 79 conformant flexible power cable up to 600 V (WTTC 1000 V), for all machinery in plant construction. Suitable for installation in dry, humid and damp environments, outdoors and pipes. For underground installation and for open, unprotected installation from the cable rack to machines in industrial plants.
• = Product conforms with Low-Voltage Directive 2014/35/EU.

technical specification:
awg-no. 18
no.of cores 16
cross section - mm² 0,963
outer ø app. - mm 13,6
cop. weight - kg/km 147,9
weight app. - kg/km 306,0
helukabel part number 62911