Helukabel 20 AWG 2 Cores JZ-603-CY Multi Approval Control Cable Oil Resistant, Cu-Screened, EMC-Preferred Cable 83709

Helukabel 20 AWG 2 Cores JZ-603-CY Multi Approval Control Cable Oil Resistant, Cu-Screened, EMC-Preferred Cable 83709

Select gauge from drop-down menu for prices:

Helukabel 20 AWG 2 Cores JZ-603-CY Multi Approval Control Cable Oil Resistant, Cu-Screened, EMC-Preferred Cable 83709
Helukabel 20 AWG 2 Cores JZ-603-CY Multi Approval Control Cable Oil Resistant, Cu-Screened, EMC-Preferred Cable 83709

Technical Data:
• Special PVC control cable with oil resistant outer sheath to DIN VDE 0285-525-2-51, DIN EN 50525-2-51 and to UL Style 2587

Temperature Range:
• HAR
Flexing -5°C to +70°C
Fixed installation -40°C to +70°C
• UL/CSA
Flexing -5°C to +90°C
Fixed installation -40°C to +90°C

Nominal Voltage:
• HAR U0/U 300/500 V
• UL/CSA 600 V

Test Voltage:3000 V

Breakdown Voltage: Min. 6000 V

Insulation Resistance: Min. 20 MOhm x km

Minimum Bending Radius:
• Flexing 10x cable Ø
• Fixed installation 5x cable Ø

Radiation Resistance: Up to 80x106 cJ/kg (up to 80 Mrad)

Coupling Resistance: Max. 250 Ohm/km

Cable Structure:
• Bare copper, fine wire conductor to DIN VDE 0295 cl.5, BS 6360 cl.5 and IEC 60228 cl.5
• Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 / DIN EN 50363-3 and class 43 acc. to UL Std.1581
• Core identification to DIN VDE 0293 black cores with continuous white numbering
• GN-YE conductor, 3 cores and above in the outer layer
• Cores stranded in layers with optimal lay length
• PVC based inner sheath
• Tinned copper braiding screening, 85% coverage
• Outer sheath of special PVC, oil resistant compound type TM5 to DIN VDE 0207-363-4-1/DIN EN 50363-4-1 and class 43 acc. to UL Std.1581
• Sheath colour: grey (RAL 7001)
• With meter marking

Properties:
• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers

Tests:
• PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B), UL VW-1, CSA FT1
• Oil resistant to DIN VDE 0473-811-404/ DIN EN 60811-404, UL 1581 part 50.182.

Note:
• G = with GN-YE conductor
• X = without GN-YE conductor (OZ)
• AWG sizes are approximate equivalent values. The actual cross section is in mm².
• Unscreened analogue type: JZ-603

Application:
• UL-CSA-HAR approved cables offer any company exporting anywhere in the world, primarily designed for exporters, used in machine tools, control systems, assembly lines and other industrial equipment. These cables are suitable for flexible use for medium mechanical stresses with free movements in dry, moist and wet rooms but not for open air.
• EMC = Electromagnetic compatibility
• To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.

technical specification
awg 20
no.cores x cross-sec. mm² 2 x 0,5
outer ø app. mm 8,0
cop. weight kg / km 41,0
weight app. kg / km 90,0
helukabel part number 83709

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.