Helukabel 26 AWG 45 Pairs PAAR-TRONIC Flexible Colour Coded To DIN 47100 Meter Marking Cable 19030

Helukabel 26 AWG 45 Pairs PAAR-TRONIC Flexible Colour Coded To DIN 47100 Meter Marking Cable 19030

Select gauge from drop-down menu for prices:

Helukabel 26 AWG 45 Pairs PAAR-TRONIC Flexible Colour Coded To DIN 47100 Meter Marking Cable 19030
Helukabel 26 AWG 45 Pairs PAAR-TRONIC Flexible Colour Coded To DIN 47100 Meter Marking Cable 19030

Technical Data:
Special-PVC data cable for electronic control adapted to DIN VDE 0812 and 0814

Temperature Range:
• Flexing -5°C to +80°C
• Fixed installation -30°C to +80°C

Operating Peak Voltage: 350 V (not for heavy current installation purposes)

Test Voltage: 1200 V

Breakdown Voltage: Min. 2400 V

Insulation Resistance: Min. 20 MOhm x km

Capacitance:
• (approx.-value) at 800 Hz
• Core/core 0,14 mm² = 120 pF/m
• Core/core 0,25 mm² = 150 pF/m

Inductance: Approx. 0,65 mH/km

Impedance: Approx. 78 Ohm

K1-Coupling: Approx. 300 pF/100 m

Minimum Bending Radius:
• Flexing 7,5x cable Ø
• Fixed installation 4x cable Ø

Radiation Resistance: Up to 80x106 cJ/kg (up to 80 Mrad)

Cable Structure:
• Bare copper-conductor, from 0,5 mm² to DIN VDE 0295 cl.5, fine-wire, BS 6360 cl.5, IEC 60228 cl.5
• Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 / DIN EN 50363-3
• Core identification (pair) to DIN 47100
• Cores stranded in pairs with optimal Tests lay-length
• Pairs stranded in layers with optimal lay-length
• Foil wrapping
• Outer sheath of special PVC compound type TM2 to DIN VDE 0207-363-4-1/DIN EN 50363-4-1
• Sheath colour grey (RAL 7032)
• With meter marking

Properties:
• Extensively oil resistant, oil-/ chemical Resistance - see table Technical Informations
• The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers

Tests:
PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1 (equivalent DIN VDE 0472 part 804 test method B)

Note:
• AWG sizes are approximate equivalent values. The actual cross-section is in mm².
• Screened analogue type: PAAR-TRONIC-CY

Application:
These data control cables are used for flexible use with free movement without tensile stress or forced movements in dry, moist and wet rooms but not suitable for open air. PAAR-TRONIC is the perfect cable for use in areas where a small diameter is essential to complete wiring. E. g. as a control and signal cable in measuring instruments, computers, signal transfer etc. This cable is suitable only for low load application.

technical specification
awg 26
no.Pairs x cross-sec. mm² 45 x 2 x 0,14
outer ø app. mm 16,4
cop. weight kg / km 121,0
weight app. kg / km 342,0
helukabel part number 19030

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.

Ask a Question