Helukabel 6 AWG 5 Cores With Green-Yellow Conductor PUR-750 Halogen Free Bare Copper Meter Marking Cable 49753

Helukabel 6 AWG 5 Cores With Green-Yellow Conductor PUR-750 Halogen Free Bare Copper Meter Marking Cable 49753

Select gauge from drop-down menu for prices:

Helukabel 6 AWG 5 Cores With Green-Yellow Conductor PUR-750 Halogen Free Bare Copper Meter Marking Cable 49753

Product Details

Technical Data:
• Special-PUR control cable adapted to DIN VDE 0285-525-2-21/DIN EN 50525-2-21

Temperature Range:
• flexing -40°C to +80°C
• (up to +100°C for short periods)

Nominal Voltage:
• up to 1 mm² U0/U 300/500 V
• from 1,5 mm² U0/U 450/750 V

Test Voltage:
• up to 1 mm² 2000 V
• from 1,5 mm² 2500 V

Insulation Resistance:
• min. 20 MOhm x km

Minimum Bending Radius:
• flexing 10x cable Ø
• fixed installation 5x cable Ø

Radiation Resistance:
• up to 100x106 cJ/kg (up to 100 Mrad)

Cable Structure:
• Bare copper-conductor, to DIN VDE 0295 cl.5, fine-wire, BS 6360 cl.5, IEC 60228 cl.5
• Core insulation PUR
• Core identification to DIN VDE 0293-308 - for 2 cores, BN, BU, - up to 5 cores coloured, - from 6 cores, black with continuous white numbering
• GN-YE conductor, 3 cores and above in the outer layer
• Cores stranded in layers with optimal lay-length
• Outer sheath of halogen-free PUR
• Sheath colour orange (RAL 2004)
• With meter marking

Properties:
• High flexibility at low temperature
• Usable for foodstuffs
• High abrasion resistance
Resistant to: Oils and fats, Non-alcoholic fuels and kerosene, Atmospheric influences, UV-radiation, Oxygene and ozone, Microbes and rotting, Sea and waste water, vibrations
• The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers

Note:
• G = with green-yellow conductor x = without green-yellow conductor (OZ)
• AWG sizes are approximate equivalent values. The actual cross-section is in mm².

Application:
Especially suited for installation in all areas demanding good performance under extreme conditions. These cable types have been successfully in use in areas such as steel works, heating and air-conditioning systems, in machinery and industrial plant equipment and on building sites etc.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

technical specification:
awg-no. 6
no.cores x cross-sec. mm² 5 G 16
outer ø app. - mm 25,9
cop. weight - kg/km 768,0
weight app. - kg/km 1180,0
helukabel part number 49753