General Cable HVTECK® 500MCM 3C 260 Mils TRXLPE Tape Shield PVC AIA PVC Power Shielded Armored 25kV CSA
Select gauge from drop-down menu for prices:
- General Cable HVTECK® 3C 260 Mils TRXLPE Tape Shield PVC AIA PVC Power Shielded Armored 25kV CSA
- General Cable HVTECK®1 AWG 3C 260 Mils TRXLPE Tape Shield PVC AIA PVC Power Shielded Armored 25kV CSA
- General Cable HVTECK® 1/0 AWG 3C 260 Mils TRXLPE Tape Shield PVC AIA PVC Power Shielded Armored 25kV CSA
- General Cable HVTECK® 2/0 AWG 3C 260 Mils TRXLPE Tape Shield PVC AIA PVC Power Shielded Armored 25kV CSA
- General Cable HVTECK® 3/0 AWG 3C 260 Mils TRXLPE Tape Shield PVC AIA PVC Power Shielded Armored 25kV CSA
- General Cable HVTECK® 4/0 AWG 3C 260 Mils TRXLPE Tape Shield PVC AIA PVC Power Shielded Armored 25kV CSA
- General Cable HVTECK® 250MCM 3C 260 Mils TRXLPE Tape Shield PVC AIA PVC Power Shielded Armored 25kV CSA
- General Cable HVTECK® 350MCM 3C 260 Mils TRXLPE Tape Shield PVC AIA PVC Power Shielded Armored 25kV CSA
Conductor: 1 AWG thru 500 kcmil bare copper compact Class B strand
Strand Shield: A thermoset semi-conducting strand shield is extruded over the conductor
Insulation: Tree-Retardant Cross-linked Polyethylene (TRXLPE)
Insulation Shield:
• This consists of a semi-conducting thermosetting layer, applied in a triple extrusion process, plus a helically applied gapped copper tape
• Color-coded: black, red or blue colored tape placed longitudinally under the copper tape shield
Ground (Bonding) Conductor: The conductor consists of one uninsulated stranded bare copper conductor
Inner Jacket: Lead-free, flame-retardant, moisture- and sunlight-resistant Polyvinyl Chloride (PVC), black
Armor: Aluminum Interlocked Armor (AIA)
Overall Jacket: Lead-free, ACID-FLAME-CHECK ??® flameretardant, moisture- and sunlight-resistant Polyvinyl Chloride (PVC), black or as requested
Options: Galvanized Steel Interlocked Armor (GSIA)
Applications:
• For wiring in all hazardous locations when used with certified HL cable glands
• For exposed and concealed wiring in dry, damp or wet locations
• For use in ventilated, non-ventilated and laddertype cable trays in dry, damp or wet locations
• For direct earth burial (with protection as required by inspection authority)
Features:
• Rated at 90?C wet or dry
• Excellent crush, oil and chemical resistance
• Provides long service life
• Cost-effective alternative to installations in conduit
• Meets cold bend and impact tests at -40?C
Compliances:
Industry Compliances:
• CSA Standard C22.2 No. 131 and No. 174
• CSA Standard C68.10
Flame Test Compliances:
• CSA FT1 and FT4
• IEEE 383 (70,000 BTU/hr)
• UL 1581 (70,000 BTU/hr)
• IEEE 1202 (70,000 BTU/hr) CSA FT4
• ICEA T-30-520 (70,000 BTU/hr)
• ICEA T-29-520 (210,000 BTU/hr)
Other Compliances:
• Hazardous Location Rating: HL
• EPA 40 CFR, Part 261 for leachable lead content per TCLP method
• OSHA Acceptable
• RoHS Compliant
Packaging:
• For Canadian customers, lengths are provided on returnable wood or steel reels that require a deposit. Extra charges apply for lagging, pulling eyes, paralleling and plexing
• For U.S. customers, material cut to length and shipped on non-returnable wood reels, while lengths in excess of 10,000 lbs. are provided on returnable steel reels that require a deposit. Extra charges apply for cuts less than 1000 ft., lagging, pulling eyes, paralleling and plexing
technical specification | |
cond. size (AWG/kcmil) | 500 |
no. of cond. | 3 |
ground wire size(AWG) | 3 |
nominal diameter (over)(insulation in inches) | 1.32 |
nominal diameter (over)(insulation in mm) | 33.5 |
nominal diameter (over)(insulation shield in inches) | 1.41 |
nominal diameter (over)(insulation shield in mm) | 35.8 |
nominal diameter (over)(inner jacket in inches) | 3.34 |
nominal diameter (over)(inner jacket in mm) | 84.9 |
nominal diameter (over)(armor in inches) | 3.63 |
nominal diameter (over)(armor in mm) | 92.2 |
nominal diameter (over)(cable in inches) | 3.76 |
nominal diameter (over)(cable in mm) | 95.5 |
copper weight(lbs/1000ft) | 5032 |
copper weight(lbs/1000ft) | 7489 |
net weight w/armor(lbs/1000ft in al) | 8950 |
net weight w/armor(lbs/1000ft in steel) | 10480 |
net weight w/armor(kg/km in al) | 13320 |
net weight w/armor(kg/km in steel) | 15590 |
outdoor ampacity** (40?c ambient) | 454 |
catalog number | 17496.856500* |