HW105 INSTRUMENTATION CABLE 600 Volt UL Type TC, 90°C Multiple Pairs Overall Shield TFN Insulation PVC Jacket Copper Conductors - 18 AWG - 36 Pairs
Select gauge from drop-down menu for prices:
- HW105 Instrumentation Cable 600 Volt UL Type TC, 90°C Multiple Pairs Overall Shield TFN Insulation PVC Jacket Copper Conductors
- HW105 INSTRUMENTATION CABLE 600 Volt UL Type TC, 90°C Multiple Pairs Overall Shield TFN Insulation PVC Jacket Copper Conductors - 18 AWG - 2 Pairs
- HW105 INSTRUMENTATION CABLE 600 Volt UL Type TC, 90°C Multiple Pairs Overall Shield TFN Insulation PVC Jacket Copper Conductors - 18 AWG - 4 Pairs
- HW105 INSTRUMENTATION CABLE 600 Volt UL Type TC, 90°C Multiple Pairs Overall Shield TFN Insulation PVC Jacket Copper Conductors - 18 AWG - 8 Pairs
- HW105 INSTRUMENTATION CABLE 600 Volt UL Type TC, 90°C Multiple Pairs Overall Shield TFN Insulation PVC Jacket Copper Conductors - 18 AWG - 12 Pairs
- HW105 INSTRUMENTATION CABLE 600 Volt UL Type TC, 90°C Multiple Pairs Overall Shield TFN Insulation PVC Jacket Copper Conductors - 18 AWG - 16 Pairs
- HW105 INSTRUMENTATION CABLE 600 Volt UL Type TC, 90°C Multiple Pairs Overall Shield TFN Insulation PVC Jacket Copper Conductors - 18 AWG - 24 Pairs
- HW105 INSTRUMENTATION CABLE 600 Volt UL Type TC, 90°C Multiple Pairs Overall Shield TFN Insulation PVC Jacket Copper Conductors - 18 AWG - 50 Pairs
- HW105 INSTRUMENTATION CABLE 600 Volt UL Type TC, 90°C Multiple Pairs Overall Shield TFN Insulation PVC Jacket Copper Conductors - 16 AWG - 2 Pairs
- HW105 INSTRUMENTATION CABLE 600 Volt UL Type TC, 90°C Multiple Pairs Overall Shield TFN Insulation PVC Jacket Copper Conductors - 16 AWG - 3 Pairs
- HW105 INSTRUMENTATION CABLE 600 Volt UL Type TC, 90°C Multiple Pairs Overall Shield TFN Insulation PVC Jacket Copper Conductors - 16 AWG - 4 Pairs
- HW105 INSTRUMENTATION CABLE 600 Volt UL Type TC, 90°C Multiple Pairs Overall Shield TFN Insulation PVC Jacket Copper Conductors - 16 AWG - 8 Pairs
- HW105 INSTRUMENTATION CABLE 600 Volt UL Type TC, 90°C Multiple Pairs Overall Shield TFN Insulation PVC Jacket Copper Conductors - 16 AWG - 12 Pairs
- HW105 INSTRUMENTATION CABLE 600 Volt UL Type TC, 90°C Multiple Pairs Overall Shield TFN Insulation PVC Jacket Copper Conductors - 16 AWG - 16 Pairs
- HW105 INSTRUMENTATION CABLE 600 Volt UL Type TC, 90°C Multiple Pairs Overall Shield TFN Insulation PVC Jacket Copper Conductors - 16 AWG - 24 Pairs
- HW105 INSTRUMENTATION CABLE 600 Volt UL Type TC, 90°C Multiple Pairs Overall Shield TFN Insulation PVC Jacket Copper Conductors - 16 AWG - 36 Pairs
- HW105 INSTRUMENTATION CABLE 600 Volt UL Type TC, 90°C Multiple Pairs Overall Shield TFN Insulation PVC Jacket Copper Conductors - 16 AWG - 50 Pairs
Technical Specifications: | |
Catalog Number | HW105 01836 |
Size AWG | 18 |
No. of Pairs | 36 |
PVC Insulation Thickness Mils | 15 |
Nylon Jacket Thickness Mils | 4 |
Overall Jacket Thickness Mils | 80 |
Overall Diameter Inch | 1.18 |
Net Weight Lbs/Mft | 796 |
Specifications:
- HW105
- INSTRUMENTATION CABLE
- 600 Volt UL Type TC, 90°C
- Multiple Pairs
- Overall Shield
- TFN Insulation
- PVC Jacket
- Copper Conductors
Application:
For use in instrumentation and process control applications where protection from electrostatic interference is required. UL listed as Type PLTC and ITC and approved for installation indoors or outdoors, aerially, in conduits, ducts and cable trays in circuits not exceeding 600 volts. May be used in NEC Class 1, Division 2 hazardous locations.
Conductors:
7-strand soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8.
Insulation:
Flame-retardant PVC.
Overall Shield:
Aluminum-polymer tape providing 100% coverage with a flexible 7-strand tinned copper drain wire.
Jacket:
Sunlight-resistant PVC. A ripcord is applied longitudinally under the jacket to facilitate stripping.
Flame Tests:
- UL 1581 70,000 BTU/hr flame test
- CSA FT4 rated
Color Code:
- ICEA Method 9: black, white and red triads with printed number
- Available upon request: black, red and blue triads with printed number
Additional Standards:
- UL Standard 13
- UL Standard 2250
- NEC Type ITC per Articles 501, 502, 503, and 504
- Approved for Class 2 and Class 3 circuits per Article 725 of the NEC