HW110 Instrumentation Cable 600 Volt UL Type TC, 90°C Multiple Pairs Individual and Overall Shield FR-EP Insulation CPE Jacket Copper Conductors - 16 AWG - 12 Triad

HW110 Instrumentation Cable 600 Volt UL Type TC, 90°C Multiple Pairs Individual and Overall Shield FR-EP Insulation CPE Jacket Copper Conductors - 16 AWG - 12 Triad

Select gauge from drop-down menu for prices:

HW110 Instrumentation Cable 600 Volt UL Type TC, 90°C Multiple Pairs Individual and Overall Shield FR-EP Insulation CPE Jacket Copper Conductors - 16 AWG - 12 Triad
HW110 Instrumentation Cable 600 Volt UL Type TC, 90°C Multiple Pairs Individual and Overall Shield FR-EP Insulation CPE Jacket Copper Conductors - 16 AWG - 12 Triad
Technical Specifications:
Catalog Number HW110 1612T
Size AWG 16
Pair or Triad
12 Triad
Insulation Thickness Mils 25
Jacket Thickness Mils 80
Overall Diameter Inch
1.14
Net Weight Lbs/Mft 705

Specifications:

  • HW110
  • Instrumentation Cable
  • 600 Volt UL Type TC, 90°C
  • Multiple Pairs
  • Individual and Overall Shield
  • FR-EP Insulation
  • CPE Jacket
  • Copper Conductors

Application:
For use in instrumentation and process control applications where protection from electrostatic interference is required. UL listed as Type PLTC and ITC and approved for installation indoors or outdoors, aerially, in conduits, ducts and cable trays in circuits not exceeding 600 volts. May be used in NEC Class 1, Division 2 hazardous locations. UL approved for NEC continuous operation at 75°C in wet locations, 90°C in dry locations, 130°C for emergency overland conditions, and 250°C for short circuit locations.

Conductors:
Tin-coated, soft annealed copper per ASTM B-33, Class B stranding per ASTM B-8 (compressed) or ASTM B-496 (compact).

Insulation:
Flame-retardant ethylene propylene rubber (FR-EP) per ICEA S-82-552.

Individual Shield:
Aluminum-polymer tape providing 100% coverage with a flexible 7-strand tinned copper drain wire.

Overall Shield:
Aluminum-polymer tape providing 100% coverage with a flexible 7-strand tinned copper drain wire.

Jacket:
Sunlight-resistant chlorinated polyethylene (CPE) per ICEA S-82-552 and UL Standard 1277. A ripcord is applied longitudinally under the jacket to facilitate stripping.

Flame Tests:

  • IEEE 383 70,000 BTU/hr flame test
  • IEEE 1202 70,000 BTU/hr
  • UL 1277 70,000 BTU/hr flame test
  • ICEA T-29-520 210,000 BTU/hr flame test
  • CSA FT4 flame test

Color Code:

  • ICEA Method 9: black and white pairs with printed number
  • Available upon request: black and red pairs with printed number

Additional Standards:

  • NEC Type TC per articles 336, 392 and 501, and Class 1 circuits per NEC article 725
  • NEMA WC-55