General Cable Mud Oil Resistant Unarmored® 2 Fibers Heavy-Duty Breakout Cable ABS Type Approval (RQS)

General Cable Mud Oil Resistant Unarmored® 2 Fibers Heavy-Duty Breakout Cable ABS Type Approval (RQS)

Product Details

Central Strength Member: Epoxy glass rod 

Optical Fiber Cable Component (OFCC): 
Fiber: 
• 2-48 fibers (see Fiber Selection Guide) 
• Color Code: White–numbered “1-ONE,” “2-TWO,” “3-THREE,” etc. 
• Buffer: polyester elastomer 900μm ± 50μm 

Strength Member: Aramid yarn longitudinally applied 

Jacket: Low-Smoke thermoplastic Polyolefin: .078" (2.0 mm) nom. diameter 

Binder Tape: Helically applied water-swellable SAP 

Aramid Yarn: Contra-helically applied and wrapped with .001" polyester binder tape 

Outer Sheath: Black Irradiated Cross-Linked Chlorosulfonated Polyethylene 

Applications: On offshore platforms, ships, mobile oil rigs, FPSOs, land rigs, onshore drilling 

Features: 
• Breakout style cable 
• Temperature: -40°C to +70°C 
• Gigabit Ethernet compliant 
• Meets NEK 606 Mud Oil Resistant requirements when tested with ester-based muds 

Compliances: 
Fiber: 
• Temp. Cycling - IEC 60794-1-2-F1 
• Tensile Strength - IEC 60794-1-2-E1A 
• Crush - IEC 60794-1-2-E3 
• Impact -  IEC 60794-1-2-E4 
• Repeated Bending - IEC 60794-1-2-E6 
• Torsion -  IEC 60794-1-2-E7 
• Kink - IEC 60794-1-2-E10 
• Cable Bend-  IEC 60794-1-2-E11 
• Cold Bend - IEC 60794-1-2-E11 

Flame:  IEC 60332-3-22 Cat. A

technical specification:
fiber count
2
nom. outer sheath diameter(inches) 0.300
nom. outer sheath diameter(mm) 7.62
nom. outer sheath thickness(inches) 0.050
nom. outer sheath thickness(mm) 1.270
maximum weight(lbs/1000 ft) 37
maximum weight(kg/km) 55
minimum bend radius(installation inches/cm) 4.8/12.2
minimum bend radius(in-service inches/cm)
2.4/6.1
maximum tensile load(installation lbs/n) 200/900
maximum tensile load(in-service lbs/n) 50/225
catalog number* XX0021C1Z-MOR