General Cable NextGen® 12 Fiber Count Loose Tube Dual Jacket Outside Plant Fiber Optic Cable
Select gauge from drop-down menu for prices:
- General Cable NextGen® Loose Tube Dual Jacket Outside Plant Fiber Optic Cable
- General Cable NextGen® 2 Fiber Count Loose Tube Dual Jacket Outside Plant Fiber Optic Cable
- General Cable NextGen® 4 Fiber Count Loose Tube Dual Jacket Outside Plant Fiber Optic Cable
- General Cable NextGen® 6 Fiber Count Loose Tube Dual Jacket Outside Plant Fiber Optic Cable
- General Cable NextGen® 8 Fiber Count Loose Tube Dual Jacket Outside Plant Fiber Optic Cable
- General Cable NextGen® 18 Fiber Count Loose Tube Dual Jacket Outside Plant Fiber Optic Cable
- General Cable NextGen® 24 Fiber Count Loose Tube Dual Jacket Outside Plant Fiber Optic Cable
- General Cable NextGen® 36 Fiber Count Loose Tube Dual Jacket Outside Plant Fiber Optic Cable
- General Cable NextGen® 48 Fiber Count Loose Tube Dual Jacket Outside Plant Fiber Optic Cable
- General Cable NextGen® 60 Fiber Count Loose Tube Dual Jacket Outside Plant Fiber Optic Cable
- General Cable NextGen® 72 Fiber Count Loose Tube Dual Jacket Outside Plant Fiber Optic Cable
- General Cable NextGen® 96 Fiber Count Loose Tube Dual Jacket Outside Plant Fiber Optic Cable
- General Cable NextGen® 120 Fiber Count Loose Tube Dual Jacket Outside Plant Fiber Optic Cable
- General Cable NextGen® 144 Fiber Count Loose Tube Dual Jacket Outside Plant Fiber Optic Cable
Fiber:
• 2–144 fibers
• Loose tube gel-filled
• Color-coding per TIA/EIA 598 B
Central Strength Member: Epoxy/glass rod
Inner Jacket: Black UV- and moisture-resistant polyethylene (PE)
Outer Jacket:
• Black UV- and moisture-resistant polyethylene (PE)
• Sequential footage markings*
Features:
• Loose tube gel-filled construction for superior fiber protection
• UV- and moisture-resistant design
• Added protection of an inner jacket
• Dry Water Block cable core for ease of handling
Performance:
• Temperature:
Storage -40?C (-40?F) to +75?C (+167?F)
Installation -30?C (-22?F) to +60?C (+140?F)
Operating -40?C (-40?F) to +70?C (+158?F)
• Minimum Bend Radius:
20 X OD—Installation
10 X OD—In-Service
• Maximum Crush Resistance:
Short - 125 lbs/in (220 N/cm)
Long - 63 lbs/in (110 N/cm)
Applications:
• Interbuilding voice or data communication backbones
• Installed in ducts, underground conduits or aerial/lashed
Compliances:
• Tested in accordance with EIA/TIA-455 FOTPs
• ICEA S-87-640
• Rural Utilities Service (RUS) 7 CFR 1755.900 (REA PE-90)
• GR-20
• RoHS Compliant Directive 2011/65/EU
Options: Alternate 6-fiber per tube available upon request
technical specification: | |
fiber count | 12 |
no. of loose tubes | 1 |
no. of fillers | 4 |
nominal cable diameter(in) | 0.51 |
nominal cable diameter(mm) | 13.0 |
nominal cable weight(lbs/1000') | 78 |
nominal cable weight(kg/km) | 116 |
maximum tensile load(installation in lbs) | 600 |
maximum tensile load(installation in n) | 2700 |
maximum tensile load(in-service in lbs) | 180 |
maximum tensile load(in-service in n) | 800 |
catalog number | XX0124H1A-DWB |