Plenum: Multi-Conductor (UL) CL2P / CMP Foil + Braid Shield - AWG 18 (19x30) Tinned Copper - 6 Cond.
Select gauge from drop-down menu for prices:
Plenum: Multi-Conductor (UL) CL2P / CMP Foil + Braid Shield - AWG 18 (19x30) Tinned Copper - 6 Cond.
- Plenum: Multi-Conductor (UL) CL2P / CMP Foil + Braid Shield - 16 - 18 AWG
- Plenum: Multi-Conductor (UL) CL2P / CMP Foil + Braid Shield - AWG 18 (19x30) Tinned Copper - 2 Cond.
- Plenum: Multi-Conductor (UL) CL2P / CMP Foil + Braid Shield - AWG 18 (19x30) Tinned Copper - 3 Cond.
- Plenum: Multi-Conductor (UL) CL2P / CMP Foil + Braid Shield - AWG 18 (19x30) Tinned Copper - 4 Cond.
- Plenum: Multi-Conductor (UL) CL2P / CMP Foil + Braid Shield - AWG 18 (19x30) Tinned Copper - 9 Cond.
- Plenum: Multi-Conductor (UL) CL2P / CMP Foil + Braid Shield - AWG 18 (19x30) Tinned Copper - 12 Cond.
- Plenum: Multi-Conductor (UL) CL2P / CMP Foil + Braid Shield - AWG 16 (19x.0117) Tinned Copper - 2 Cond.
- Plenum: Multi-Conductor (UL) CL2P / CMP Foil + Braid Shield - AWG 16 (19x.0117) Tinned Copper - 3 Cond.
- Plenum: Multi-Conductor (UL) CL2P / CMP Foil + Braid Shield - AWG 16 (19x.0117) Tinned Copper - 4 Cond.
- Plenum: Multi-Conductor (UL) CL2P / CMP Foil + Braid Shield - AWG 16 (19x.0117) Tinned Copper - 6 Cond.
- Plenum: Multi-Conductor (UL) CL2P / CMP Foil + Braid Shield - AWG 16 (19x.0117) Tinned Copper - 9 Cond.
- Plenum: Multi-Conductor (UL) CL2P / CMP Foil + Braid Shield - AWG 16 (19x.0117) Tinned Copper - 12 Cond.
- Plenum: Multi-Conductor (UL) CL2P / CMP Foil + Braid Shield - AWG 16 (19x.0117) Tinned Copper - 19 Cond.
- Plenum: Multi-Conductor (UL) CL2P / CMP Foil + Braid Shield - AWG 16 (19x.0117) Tinned Copper - 15 Cond.
Product Details
Technical Specifications: | |
Aero P/N | 1654/19R |
AWG | 18 |
No. of Cond. | 6 |
Insulation Thickness (inches) | .007 |
Jacket Thickness (inches) | .015 |
Jacket O.D. (inches) | .243 |
Lbs/1000' | 74 |
Specifications:
- Plenum: Multi-Conductor (UL)
- CL2P / CMP Foil + Braid Shield
- Plenum: [18 - 16 AWG ]
- Compliance: (UL) c(UL) CL2P or CMP
- FEP 200°C, E-CTFE 150°C and LS PVC 60°C
Conductor:
Stranded T.C.
Insulation:
FEP
Color Code:
Chart 2
Shield:
Foil & TC Braid
Jackets Available:
- FEP (200°C) or
- E-CTFE (150°C) Add "K" to P/N or
- Plenum PVC Jacket available
Industry Approvals:
- NEC Article 800-CMP
Impedance: (FEP only):
- (AWG 18) 40 Ohms Nom.
- (AWG 16) 35 Ohms Nom.
Vel. of Propagation: (FEP only)
69% Nom.
Capacitance: (FEP only)
- (AWG 18) 38 pF/ft Nom.
- (AWG 16) 42 pF/ft Nom.
Temperature Rating:
- -80°C to +200°C (FEP/FEP)
- -40°C to +150°C (FEP/E-CTFE)
Put Ups:
- 1000 Feet (+/- 10%)
- (Available in Bulk Reels)