Plenum: Multi-Pair (UL) CL2P / CMP Shielded - 20 AWG (7x28) Tinned Copper - 7 Pairs
Select gauge from drop-down menu for prices:
Plenum: Multi-Pair (UL) CL2P / CMP Shielded - 20 AWG (7x28) Tinned Copper - 7 Pairs
- Plenum: Multi-Pair (UL) CL2P / CMP Shielded - 18-20 AWG
- Plenum: Multi-Pair (UL) CL2P / CMP Shielded - 20 AWG (7x28) Tinned Copper - 2 Pairs
- Plenum: Multi-Pair (UL) CL2P / CMP Shielded - 20 AWG (7x28) Tinned Copper - 3 Pairs
- Plenum: Multi-Pair (UL) CL2P / CMP Shielded - 20 AWG (7x28) Tinned Copper - 4 Pairs
- Plenum: Multi-Pair (UL) CL2P / CMP Shielded - 20 AWG (7x28) Tinned Copper - 5 Pairs
- Plenum: Multi-Pair (UL) CL2P / CMP Shielded - 20 AWG (7x28) Tinned Copper - 6 Pairs
- Plenum: Multi-Pair (UL) CL2P / CMP Shielded - 20 AWG (7x28) Tinned Copper - 8 Pairs
- Plenum: Multi-Pair (UL) CL2P / CMP Shielded - 20 AWG (7x28) Tinned Copper - 9 Pairs
- Plenum: Multi-Pair (UL) CL2P / CMP Shielded - 20 AWG (7x28) Tinned Copper - 10 Pairs
- Plenum: Multi-Pair (UL) CL2P / CMP Shielded - 20 AWG (7x28) Tinned Copper - 12 Pairs
- Plenum: Multi-Pair (UL) CL2P / CMP Shielded - 20 AWG (7x28) Tinned Copper - 15 Pairs
- Plenum: Multi-Pair (UL) CL2P / CMP Shielded - 20 AWG (7x28) Tinned Copper - 18 Pairs
- Plenum: Multi-Pair (UL) CL2P / CMP Shielded - 20 AWG (7x28) Tinned Copper - 20 Pairs
- Plenum: Multi-Pair (UL) CL2P / CMP Shielded - 20 AWG (7x28) Tinned Copper - 25 Pairs
- Plenum: Multi-Pair (UL) CL2P / CMP Shielded - 20 AWG (7x28) Tinned Copper - 30 Pairs
- Plenum: Multi-Pair (UL) CL2P / CMP Shielded - 18 AWG (7x26) Tinned Copper - 2 Pairs
- Plenum: Multi-Pair (UL) CL2P / CMP Shielded - 18 AWG (7x26) Tinned Copper - 3 Pairs
- Plenum: Multi-Pair (UL) CL2P / CMP Shielded - 18 AWG (7x26) Tinned Copper - 4 Pairs
- Plenum: Multi-Pair (UL) CL2P / CMP Shielded - 18 AWG (7x26) Tinned Copper - 5 Pairs
- Plenum: Multi-Pair (UL) CL2P / CMP Shielded - 18 AWG (7x26) Tinned Copper - 6 Pairs
- Plenum: Multi-Pair (UL) CL2P / CMP Shielded - 18 AWG (7x26) Tinned Copper - 7 Pairs
- Plenum: Multi-Pair (UL) CL2P / CMP Shielded - 18 AWG (7x26) Tinned Copper - 8 Pairs
- Plenum: Multi-Pair (UL) CL2P / CMP Shielded - 18 AWG (7x26) Tinned Copper - 9 Pairs
- Plenum: Multi-Pair (UL) CL2P / CMP Shielded - 18 AWG (7x26) Tinned Copper - 10 Pairs
- Plenum: Multi-Pair (UL) CL2P / CMP Shielded - 18 AWG (7x26) Tinned Copper - 12 Pairs
- Plenum: Multi-Pair (UL) CL2P / CMP Shielded - 18 AWG (7x26) Tinned Copper - 15 Pairs
- Plenum: Multi-Pair (UL) CL2P / CMP Shielded - 18 AWG (7x26) Tinned Copper - 18 Pairs
- Plenum: Multi-Pair (UL) CL2P / CMP Shielded - 18 AWG (7x26) Tinned Copper - 20 Pairs
- Plenum: Multi-Pair (UL) CL2P / CMP Shielded - 18 AWG (7x26) Tinned Copper - 25 Pairs
- Plenum: Multi-Pair (UL) CL2P / CMP Shielded - 18 AWG (7x26) Tinned Copper - 30 Pairs
Plenum: Multi-Pair (UL) CL2P / CMP Shielded - 20 AWG (7x28) Tinned Copper - 7 Pairs
Technical Specifications: | |
Aero P/N | 2740 |
AWG | 20 |
No. of Pairs | 7 |
Insulation Thickness (inches) | .006 |
Jacket Thickness (inches) | .012 |
Jacket O.D. (inches) | .278 |
Lbs/1000' | 77 |
Specifications:
- Plenum: Multi-Pair (UL)
- CL2P / CMP Shielded
- Plenum: [Multi-Pairs (UL) CL2P/CMP Foil Shield: 20 & 18 AWG (200°C or 150°C) ] (Color Code Chart)
- Stranded. (UL) CL2P or CMP. 200°C or 150°C.
Conductor:
Stranded T.C.
Insulation:
FEP or Halar (ECTFE) Add "HL" to P/N
Color Code:
Chart 3
Shield:
Aluminum/Mylar
Jackets Available:
- FEP (200°C) or
- PVDF (150°C) Add "K" to P/N or
- Plenum PVC Jacket available
Industry Approvals:
- NEC Article 725-CL2P or
- NEC Article 800-CMP
- PCC FT6-C(UL) (CMP only)
Impedance: (FEP only)
- (AWG 18) 72 Ohms Nom.
- (AWG 20) 78 Ohms Nom.
Vel. of Propagation: (FEP only)
69% Nom.
Capacitance: (FEP only)
- (AWG 18) 20.5 pF/ft Nom.
- (AWG 20) 19.1 pF/ft Nom.
Temperature Rating:
- -80°C to +200°C (FEP/FEP)
- -20°C to +150°C (FEP/PVDF)
- -5°C to +75°C (Halar/Aeroflex)
Put Ups:
- 1000 Feet (+/- 10%)
- (Available in Bulk Reels)