Plenum: Multi-Pair (UL) CL2P / CMP Shielded - AWG 24 (7x32) Tinned Copper - 15 Conductors
Select gauge from drop-down menu for prices:
Plenum: Multi-Pair (UL) CL2P / CMP Shielded - AWG 24 (7x32) Tinned Copper - 15 Conductors
- Plenum: Multi-Pair (UL) CL2P / CMP Shielded
- Plenum: Multi-Pair (UL) CL2P / CMP Shielded - AWG 24 (7x32) Tinned Copper - 2 Conductors
- Plenum: Multi-Pair (UL) CL2P / CMP Shielded - AWG 24 (7x32) Tinned Copper - 3 Conductors
- Plenum: Multi-Pair (UL) CL2P / CMP Shielded - AWG 24 (7x32) Tinned Copper - 3 Conductors 2370*
- Plenum: Multi-Pair (UL) CL2P / CMP Shielded - AWG 24 (7x32) Tinned Copper - 4 Conductors
- Plenum: Multi-Pair (UL) CL2P / CMP Shielded - AWG 24 (7x32) Tinned Copper - 4 Conductors 2470*
- Plenum: Multi-Pair (UL) CL2P / CMP Shielded - AWG 24 (7x32) Tinned Copper - 5 Conductors
- Plenum: Multi-Pair (UL) CL2P / CMP Shielded - AWG 24 (7x32) Tinned Copper - 5 Conductors 2570*
- Plenum: Multi-Pair (UL) CL2P / CMP Shielded - AWG 24 (7x32) Tinned Copper - 6 Conductors
- Plenum: Multi-Pair (UL) CL2P / CMP Shielded - AWG 24 (7x32) Tinned Copper - 7 Conductors
- Plenum: Multi-Pair (UL) CL2P / CMP Shielded - AWG 24 (7x32) Tinned Copper - 8 Conductors
- Plenum: Multi-Pair (UL) CL2P / CMP Shielded - AWG 24 (7x32) Tinned Copper - 9 Conductors
- Plenum: Multi-Pair (UL) CL2P / CMP Shielded - AWG 24 (7x32) Tinned Copper - 10 Conductors
- Plenum: Multi-Pair (UL) CL2P / CMP Shielded - AWG 24 (7x32) Tinned Copper - 12.5 Conductors
- Plenum: Multi-Pair (UL) CL2P / CMP Shielded - AWG 28 (7x36) Tinned Copper - 13 Conductors
- Plenum: Multi-Pair (UL) CL2P / CMP Shielded - AWG 24 (7x32) Tinned Copper - 16 Conductors
- Plenum: Multi-Pair (UL) CL2P / CMP Shielded - AWG 24 (7x32) Tinned Copper - 18 Conductors
- Plenum: Multi-Pair (UL) CL2P / CMP Shielded - AWG 24 (7x32) Tinned Copper - 18.5 Conductors
- Plenum: Multi-Pair (UL) CL2P / CMP Shielded - AWG 24 (7x32) Tinned Copper - 19 Conductors
- Plenum: Multi-Pair (UL) CL2P / CMP Shielded - AWG 24 (7x32) Tinned Copper - 20 Conductors
- Plenum: Multi-Pair (UL) CL2P / CMP Shielded - AWG 24 (7x32) Tinned Copper - 22 Conductors
- Plenum: Multi-Pair (UL) CL2P / CMP Shielded - AWG 24 (7x32) Tinned Copper - 25 Conductors
- Plenum: Multi-Pair (UL) CL2P / CMP Shielded - AWG 24 (7x32) Tinned Copper - 31 Conductors
Plenum: Multi-Pair (UL) CL2P / CMP Shielded - AWG 24 (7x32) Tinned Copper - 15 Conductors
Technical Specifications: | |
Aero P/N | 2170-15 |
AWG | 24 |
No. of Cond. | 15 |
Insulation Thickness (inches) | .006 |
Jacket Thickness (inches) | .010 |
Jacket O.D. (inches) | .294 |
Lbs/1000' | 69 |
Specifications:
- Plenum: Multi-Pair (UL)
- CL2P / CMP Shielded
- Mid-Capacitance Plenum Cable: [ Mid-Capacitance Cables: 28 & 24 AWG (200°C) ] [ Multi-Pairs (UL) CL2P/CMP Foil Shield: 28 & 24 AWG (200°C, 150°C or 75°C) ] (Color Code Chart)
- Stranded. (UL) CL2P or CMP. 200°C, 150°C or 75°C.
Conductor:
Stranded T.C.
Insulation:
FEP
Color Code:
Chart 3
Shield:
Aluminum/Mylar
Jackets Available:
- FEP (200°C)
- E-CTFE (150°C) Add "K" to P/N
- Aeroflex (75°C) Add PV to P/N
Industry Approvals:
- NEC Article 725-CL2P
- NEC Article 800-CMP
- C(UL) (CMP only)
Impedance: (FEP only)
- (AWG 28) 110 Ohms Nom.
- (AWG 24) 90 Ohms Nom.
Vel. of Propagation: (FEP only)
69% Nom.
Capacitance: (FEP only)
- (AWG 28) 13.4 pF/ft Nom.
- (AWG 24) 16.2 pF/ft Nom.
Temperature Rating:
- -80°C to +200°C (FEP/FEP)
- -40°C to +150°C (FEP/E-CTFE)
Put Ups:
- 1000 Feet (+/- 10%)
- (Available in Bulk Reels)
Add to P/N:
- *RD = Red Jacket, CMP 200°C
- *KRD = Red Jacket, CMP 150°C
- *PV = Aeroflex Jacket, 75°C