Plenum: Multi-Pair (UL) CL2P / CMP Unshielded - 20 AWG - (7x28) Tinned Copper - 6 Cond
Select gauge from drop-down menu for prices:
Plenum: Multi-Pair (UL) CL2P / CMP Unshielded - 20 AWG - (7x28) Tinned Copper - 6 Cond
- Plenum: Multi-Pair (UL) CL2P / CMP Unshielded 20 - 24 AWG
- Plenum: Multi-Pair (UL) CL2P / CMP Unshielded - 24 AWG - (7x32) Tinned Copper - 2 Cond
- Plenum: Multi-Pair (UL) CL2P / CMP Unshielded - 24 AWG - (7x32) Tinned Copper - 3 Cond
- Plenum: Multi-Pair (UL) CL2P / CMP Unshielded - 24 AWG - (7x32) Tinned Copper - 6 Cond
- Plenum: Multi-Pair (UL) CL2P / CMP Unshielded - 24 AWG - (7x32) Tinned Copper - 8 Cond
- Plenum: Multi-Pair (UL) CL2P / CMP Unshielded - 24 AWG - (7x32) Tinned Copper - 10 Cond
- Plenum: Multi-Pair (UL) CL2P / CMP Unshielded - 24 AWG - (7x32) Tinned Copper - 15 Cond
- Plenum: Multi-Pair (UL) CL2P / CMP Unshielded - 24 AWG - (7x32) Tinned Copper - 20 Cond
- Plenum: Multi-Pair (UL) CL2P / CMP Unshielded - 24 AWG - (7x32) Tinned Copper - 25 Cond
- Plenum: Multi-Pair (UL) CL2P / CMP Unshielded - 22 AWG - (7x30) - Tinned Copper - 2 Cond
- Plenum: Multi-Pair (UL) CL2P / CMP Unshielded - 22 AWG - (7x30) Tinned Copper - 3 Cond
- Plenum: Multi-Pair (UL) CL2P / CMP Unshielded - 22 AWG - (7x30) - Tinned Copper - 6 Cond
- Plenum: Multi-Pair (UL) CL2P / CMP Unshielded - 22 AWG - (7x30) Tinned Copper - 8 Cond
- Plenum: Multi-Pair (UL) CL2P / CMP Unshielded - 22 AWG - (7x30) Tinned Copper - 10 Cond
- Plenum: Multi-Pair (UL) CL2P / CMP Unshielded - 22 AWG - (7x30) Tinned Copper - 15 Cond
- Plenum: Multi-Pair (UL) CL2P / CMP Unshielded - 22 AWG - (7x30) Tinned Copper - 20 Cond
- Plenum: Multi-Pair (UL) CL2P / CMP Unshielded - 22 AWG - (7x30) Tinned Copper - 25 Cond
- Plenum: Multi-Pair (UL) CL2P / CMP Unshielded - 22 AWG - (7x30) Tinned Copper - 37 Cond
- Plenum: Multi-Pair (UL) CL2P / CMP Unshielded - 20 AWG - (7x28) Tinned Copper - 2 Cond
- Plenum: Multi-Pair (UL) CL2P / CMP Unshielded - 20 AWG - (7x28) Tinned Copper - 3 Cond
- Plenum: Multi-Pair (UL) CL2P / CMP Unshielded - 20 AWG - (7x28) Tinned Copper - 8 Cond
- Plenum: Multi-Pair (UL) CL2P / CMP Unshielded - 20 AWG - (7x28) Tinned Copper - 10 Cond
- Plenum: Multi-Pair (UL) CL2P / CMP Unshielded - 20 AWG - (7x28) Tinned Copper - 15 Cond
- Plenum: Multi-Pair (UL) CL2P / CMP Unshielded - 20 AWG - (7x28) Tinned Copper - 20 Cond
- Plenum: Multi-Pair (UL) CL2P / CMP Unshielded - 20 AWG - (7x28) Tinned Copper - 25 Cond
Product Details
Technical Specifications: | |
Aero P/N | 2642 |
AWG | 20 |
No. of Cond. | 6 |
Insulation Thickness (inches) | .006 |
Jacket Thickness (inches) | .012 |
Jacket O.D. (inches) | .336 |
Lbs/1000' | 89 |
Specifications:
- Plenum: Multi-Pair (UL)
- CL2P / CMP Unshielded
- Plenum: [Multi-Pairs (UL) CL2P/CMP Individual Shield: 24 thru 20
- AWG (200°C or 150°C) ] (Color Code Chart)
- Stranded. (UL) CL2P or CMP. 200°C or 150°C.
Conductor:
Stranded T.C.
Insulation:
FEP or Halar (ECTFE) Add "HL" to P/N
Color Code:
Chart 3 Except: ‡ Black/Red, White/Green
Shield:
Individual Foil Shield and Drain † Common drain wire
Jackets Available:
- FEP (200°C) or
- PVDF (150°C) Add "K" to P/N or
- Plenum PVC Jacket available
Industry Approvals:
- NEC Article 800-CMP
- PCC FT6-C(UL) (CMP only)
Impedance: (FEP only):
- (AWG 24) 55 Ohms Nom.
- (AWG 22) 50 Ohms Nom.
- (AWG 20) 45 Ohms Nom.
Vel. of Propagation: (FEP only)
69% Nom.
Capacitance: (FEP only)
- (AWG 24) 27.3 pF/ft Nom.
- (AWG 22) 30.6 pF/ft Nom.
- (AWG 20) 34.2 pF/ft Nom.
Temperature Rating:
- -80°C to +200°C (FEP/FEP)
- -20°C to +150°C (FEP/PVDF)
- -5°C to +75°C (Halar/PVDF)
Put Ups:
- 1000 Feet (+/- 10%)
- (Available in Bulk Reels)
Add to P/N:
*R = for Red Jacket CMP
Conductor Temp Rating:
150°C