TRAY CABLE - PLTC TRIADS WITH OVERALL SHIELD PVC Insulation with Overall PVC Jacket TYPE PLTC/ITC-ER - INSTRUMENTATION TRAY CABLE 300 Volts - 105 Degrees C - 16 AWG - 8 Pairs
Select gauge from drop-down menu for prices:
TRAY CABLE - PLTC TRIADS WITH OVERALL SHIELD PVC Insulation with Overall PVC Jacket TYPE PLTC/ITC-ER - INSTRUMENTATION TRAY CABLE 300 Volts - 105 Degrees C - 16 AWG - 8 Pairs
- Tray Cable - PLTC Triads With Overall Shield PVC Insulation with Overall PVC Jacket TYPE PLTC/ITC-ER - Instrumentation Tray Cable 300 Volts - 105 Degrees C
- TRAY CABLE - PLTC TRIADS WITH OVERALL SHIELD PVC Insulation with Overall PVC Jacket TYPE PLTC/ITC-ER - INSTRUMENTATION TRAY CABLE 300 Volts - 105 Degrees C - 20 AWG - 1 Pair
- TRAY CABLE - PLTC TRIADS WITH OVERALL SHIELD PVC Insulation with Overall PVC Jacket TYPE PLTC/ITC-ER - INSTRUMENTATION TRAY CABLE 300 Volts - 105 Degrees C - 20 AWG - 2 Pairs
- TRAY CABLE - PLTC TRIADS WITH OVERALL SHIELD PVC Insulation with Overall PVC Jacket TYPE PLTC/ITC-ER - INSTRUMENTATION TRAY CABLE 300 Volts - 105 Degrees C - 20 AWG - 4 Pairs
- TRAY CABLE - PLTC TRIADS WITH OVERALL SHIELD PVC Insulation with Overall PVC Jacket TYPE PLTC/ITC-ER - INSTRUMENTATION TRAY CABLE 300 Volts - 105 Degrees C - 20 AWG - 8 Pairs
- TRAY CABLE - PLTC TRIADS WITH OVERALL SHIELD PVC Insulation with Overall PVC Jacket TYPE PLTC/ITC-ER - INSTRUMENTATION TRAY CABLE 300 Volts - 105 Degrees C - 20 AWG - 12 Pairs
- TRAY CABLE - PLTC TRIADS WITH OVERALL SHIELD PVC Insulation with Overall PVC Jacket TYPE PLTC/ITC-ER - INSTRUMENTATION TRAY CABLE 300 Volts - 105 Degrees C - 18 AWG - 1 Pair
- TRAY CABLE - PLTC TRIADS WITH OVERALL SHIELD PVC Insulation with Overall PVC Jacket TYPE PLTC/ITC-ER - INSTRUMENTATION TRAY CABLE 300 Volts - 105 Degrees C - 18 AWG - 2 Pairs
- TRAY CABLE - PLTC TRIADS WITH OVERALL SHIELD PVC Insulation with Overall PVC Jacket TYPE PLTC/ITC-ER - INSTRUMENTATION TRAY CABLE 300 Volts - 105 Degrees C - 18 AWG - 4 Pairs
- TRAY CABLE - PLTC TRIADS WITH OVERALL SHIELD PVC Insulation with Overall PVC Jacket TYPE PLTC/ITC-ER - INSTRUMENTATION TRAY CABLE 300 Volts - 105 Degrees C - 18 AWG - 8 Pairs
- TRAY CABLE - PLTC TRIADS WITH OVERALL SHIELD PVC Insulation with Overall PVC Jacket TYPE PLTC/ITC-ER - INSTRUMENTATION TRAY CABLE 300 Volts - 105 Degrees C - 18 AWG - 12 Pairs
- TRAY CABLE - PLTC TRIADS WITH OVERALL SHIELD PVC Insulation with Overall PVC Jacket TYPE PLTC/ITC-ER - INSTRUMENTATION TRAY CABLE 300 Volts - 105 Degrees C - 16 AWG - 1 Pair
- 16 AWG 2 Pair PVC-Insulated Triads Instrumentation Tray Cable, 300V, 105°C
- TRAY CABLE - PLTC TRIADS WITH OVERALL SHIELD PVC Insulation with Overall PVC Jacket TYPE PLTC/ITC-ER - INSTRUMENTATION TRAY CABLE 300 Volts - 105 Degrees C - 16 AWG - 4 Pairs
- 16 AWG 12 Pair PVC-Insulated Triads Instrumentation Tray Cable, 300V, 105°C
TRAY CABLE - PLTC TRIADS WITH OVERALL SHIELD PVC Insulation with Overall PVC Jacket TYPE PLTC/ITC-ER - INSTRUMENTATION TRAY CABLE 300 Volts - 105 Degrees C - 16 AWG - 8 Pairs
Technical Specifications: | |
Catalog Number | 16008TOS |
AWG | 16 |
No. of Pairs | 8 |
OA Jkt. Thick. (MILS) | 60 |
Appr. O.D. (IN) | .715 |
Appr. Weight Lbs./ M Ft. | 325 |
Stranding | 7 |
PVC Insulation Thickness | 15 |
Appr. O.D. (IN) | .087 |
Specifications:
- TRAY CABLE - PLTC TRIADS WITH OVERALL SHIELD
- TYPE PLTC/ITC-ER - INSTRUMENTATION TRAY CABLE
- Triads with Overall Shield PVC Insulation with Overall PVC Jacket
- 20 - 16 AWG • 300 Volts • 105°C
Description:
ADC’s Type PLTC/ITC-ER triads with an overall shield have a PVC insulation, aluminum tape shield with drain wire and an overall sunlight resistant PVC jacket.
Application:
Class 1 Division 2 Industrial Hazardous Locations. For use in cable tray, raceway and conduit. For use with audio, intercom, control, energy management, and alarm circuits. For use where sunlight resistance is required.
Construction:
- Conductors: Soft Drawn Annealed Bare Copper per ASTM B-3 and B-8. Concentric 7 strand. Tinned Copper available upon request.
- Insulation: PVC Thickness: Per UL 13 Table 7.3
- Cabling: Triads are cabled with staggered lay.
- Overall Shield: Aluminum mylar tape providing 100% coverage with a flexible stranded tinned copper drain wire.
- Overall Jacket: A black, fame resistant, Polyvinyl Chloride (PVC) jacket is extruded over the assembly. The surface profile shall approximate that of the interior assembly. A rip cord shall be inserted under the jacket for ease of stripping.
- Color Code: Method 1 - Black, White and Red (White conductor in each triad printed alphanumerically for easy identification)
Industry Listings & Standards:
- UL Listed as PLTC/ITC per UL Standard 13 and 2250
- Rated -25°C to 105°C
- OSHA Acceptable
- NEC Article 725
- CSA FT4
- IEEE1202 70,000 BTU Flame Test
- ASTM - All Applicable Standards