General Cable Polyrad® XT-TX 1 AWG 225/24 Stranding Flexible Wire and Cable 2000 V Single Conductor NYCT Type TX

General Cable Polyrad® XT-TX 1 AWG 225/24 Stranding Flexible Wire and Cable 2000 V Single Conductor NYCT Type TX

Select gauge from drop-down menu for prices:

General Cable Polyrad® XT-TX 1 AWG 225/24 Stranding Flexible Wire and Cable 2000 V Single Conductor NYCT Type TX
Polyrad XT-TX 1 AWG 225/24 Stranding Flexible Wire and Cable 2000 V Single Conductor NYCT Type TX

Conductor: 20 AWG thru 535 kcmil soft annealed tinned copper per ASTM B33, B8 and B172

Insulation: Polyrad® XT flame-retardant, low-smoke irradiated Cross-linked Polyolefin (XLPO)

Options: Available in colors other than dark gray

Applications:
• Ideally suited for use where environmental factors require cable characteristics to perform with a high degree of flame retardancy and excellent moisture-stable electrical values. Where reliability is the major concern and where maximum performance will be demanded
• Engineered and manufactured for both original equipment and retrofit use in power and control circuits and in motor leads
• Extensively found on all types of heavy- and light-rail cars, rapid transit cars, dieselelectric locomotives, freight cars and off-road vehicles

Features:
• Cables meet NYCT TX specification
• Temperature rating at 110ºC
• Excellent flexibility and free stripping
• Outstanding thermal stability at elevated temperatures
• Maximum flame retardance and low toxicity
• Excellent low-temperature performance; suitable for installation in sub-zero conditions
• Extra-tough, mechanically rugged irradiated thermoset insulation
• Resistant to most oils and chemicals
• Meets cold bend test at –55ºC
• Meets cold impact test at –40ºC

Compliances:
Industry:
• AAR S-501/AAR RP-585
• ICEA S-95-658
Flame Test:
• IEEE 1202 (70,000 BTU/hr)
• IEEE 383 (70,000 BTU/hr)
• VW-1
Other:
• Meets NYCT TX specification
• BSS 7239
• SMP 800-C
• ASTM E662
• NFPA 130 STD 2010

Packaging: Standard reel put-up

technical specification:
conductor size(awg/kcmil) 1
conductor(stranding) 225/24
nominal conductor diameter(inches) 0.380
nominal conductor diameter(mm) 9.65
minimum average insulation thickness(mils) 65
minimum average insulation thickness(mm) 1.65
nominal cable diameter(inches) 0.514
nominal cable diameter(mm) 13.06
copper weight(lbs./1000') 287
copper weight(kg/km) 427
net cable weight(lbs./1000') 357
net cable weight(kg/km) 531
ampacity(free air 40?c ambient) (110?c) 247
nyct type tx stock code number 20-90-380X
catalog number 390250

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.

Ask a Question